Radmetron
+375 (17) 336 68 68
+375 (17) 336 68 68 Phone
+375 (44) 773 44 44 Phone
E-mail
info@radmetron.com
Catalog
  • Dosimeters
    • Electronic Dosimeters
    • Personal Dosimeters
  • Personal Radiation Detectors
    • Gamma-Neutron PRDs
    • Gamma PRDs
  • Radiation Portal Monitors
    • Transport RPMs
    • Pedestrian & Luggage RPMs
  • Radionuclide Identification Devices
  • Smart Probes
  • Contamination Measurement Radiometers
  • Contraband Detector
  • Chemical Agent Detection Equipment
  • Radiation Monitoring System
  • Gamma and Neutron Radiation Calibration Equipment
  • System Software
Applications
  • Nuclear Power
    • Personnel Exposure
    • Access Control
    • Workplace Safety
    • Calibration and Verification Equipment
  • Medical
    • Personnel Exposure
    • Radiation Area Monitoring
    • Waste control
  • Homeland Security
    • Radiation Security of Public Events & Sites
    • Emergency Response
    • Illicit Trafficking of Nuclear and Radioactive Materials
  • Oil & Gas | Mining
    • Exploration Geology
    • Soil Inspection
    • Inspection of Raw Materials, Waste & Goods
    • Surface Contamination
    • Radiation Safety in NDT
  • Industrial Safety
    • Personnel Exposure
    • Internal Control of IR sources
    • Inspection of Raw Materials, Waste & Goods
    • Laboratory Equipment
Services
  • Design and development
  • Commissioning
  • Trainings
  • Maintenance
Company
  • About Us
  • Company details
  • Certificates
  • News
  • Articles
Dealers
Support
Contacts
EN
RU
EN
+375 (17) 336 68 68
+375 (17) 336 68 68 Phone
+375 (44) 773 44 44 Phone
E-mail
info@radmetron.com
EN
RU
EN
Radmetron
Creation of innovative radiation control devices and systems to ensure human safety
Catalog
  • Dosimeters
    Dosimeters
    • Electronic Dosimeters
    • Personal Dosimeters
  • Personal Radiation Detectors
    Personal Radiation Detectors
    • Gamma-Neutron PRDs
    • Gamma PRDs
  • Radiation Portal Monitors
    Radiation Portal Monitors
    • Transport RPMs
    • Pedestrian & Luggage RPMs
  • Radionuclide Identification Devices
    Radionuclide Identification Devices
  • Smart Probes
    Smart Probes
  • Contamination Measurement Radiometers
    Contamination Measurement Radiometers
  • Contraband Detector
    Contraband Detector
  • Chemical Agent Detection Equipment
    Chemical Agent Detection Equipment
  • Radiation Monitoring System
    Radiation Monitoring System
  • Gamma and Neutron Radiation Calibration Equipment
    Gamma and Neutron Radiation Calibration Equipment
  • System Software
    System Software
Applications
  • Nuclear Power
    Nuclear Power
    • Personnel Exposure
    • Access Control
    • Workplace Safety
    • Calibration and Verification Equipment
  • Medical
    Medical
    • Personnel Exposure
    • Radiation Area Monitoring
    • Waste control
  • Homeland Security
    Homeland Security
    • Radiation Security of Public Events & Sites
    • Emergency Response
    • Illicit Trafficking of Nuclear and Radioactive Materials
  • Oil & Gas | Mining
    Oil & Gas | Mining
    • Exploration Geology
    • Soil Inspection
    • Inspection of Raw Materials, Waste & Goods
    • Surface Contamination
    • Radiation Safety in NDT
  • Industrial Safety
    Industrial Safety
    • Personnel Exposure
    • Internal Control of IR sources
    • Inspection of Raw Materials, Waste & Goods
    • Laboratory Equipment
Services
  • Design and development
  • Commissioning
  • Trainings
  • Maintenance
Company
  • About Us
  • Company details
  • Certificates
  • News
  • Articles
Dealers
Support
Contacts
    Radmetron
    Catalog
    • Dosimeters
      Dosimeters
      • Electronic Dosimeters
      • Personal Dosimeters
    • Personal Radiation Detectors
      Personal Radiation Detectors
      • Gamma-Neutron PRDs
      • Gamma PRDs
    • Radiation Portal Monitors
      Radiation Portal Monitors
      • Transport RPMs
      • Pedestrian & Luggage RPMs
    • Radionuclide Identification Devices
      Radionuclide Identification Devices
    • Smart Probes
      Smart Probes
    • Contamination Measurement Radiometers
      Contamination Measurement Radiometers
    • Contraband Detector
      Contraband Detector
    • Chemical Agent Detection Equipment
      Chemical Agent Detection Equipment
    • Radiation Monitoring System
      Radiation Monitoring System
    • Gamma and Neutron Radiation Calibration Equipment
      Gamma and Neutron Radiation Calibration Equipment
    • System Software
      System Software
    Applications
    • Nuclear Power
      Nuclear Power
      • Personnel Exposure
      • Access Control
      • Workplace Safety
      • Calibration and Verification Equipment
    • Medical
      Medical
      • Personnel Exposure
      • Radiation Area Monitoring
      • Waste control
    • Homeland Security
      Homeland Security
      • Radiation Security of Public Events & Sites
      • Emergency Response
      • Illicit Trafficking of Nuclear and Radioactive Materials
    • Oil & Gas | Mining
      Oil & Gas | Mining
      • Exploration Geology
      • Soil Inspection
      • Inspection of Raw Materials, Waste & Goods
      • Surface Contamination
      • Radiation Safety in NDT
    • Industrial Safety
      Industrial Safety
      • Personnel Exposure
      • Internal Control of IR sources
      • Inspection of Raw Materials, Waste & Goods
      • Laboratory Equipment
    Services
    • Design and development
    • Commissioning
    • Trainings
    • Maintenance
    Company
    • About Us
    • Company details
    • Certificates
    • News
    • Articles
    Dealers
    Support
    Contacts
      EN
      RU
      Radmetron
      Radmetron
      • Catalog
        • Catalog
        • Dosimeters
          • Dosimeters
          • Electronic Dosimeters
          • Personal Dosimeters
        • Personal Radiation Detectors
          • Personal Radiation Detectors
          • Gamma-Neutron PRDs
          • Gamma PRDs
        • Radiation Portal Monitors
          • Radiation Portal Monitors
          • Transport RPMs
          • Pedestrian & Luggage RPMs
        • Radionuclide Identification Devices
        • Smart Probes
        • Contamination Measurement Radiometers
        • Contraband Detector
        • Chemical Agent Detection Equipment
        • Radiation Monitoring System
        • Gamma and Neutron Radiation Calibration Equipment
        • System Software
      • Applications
        • Applications
        • Nuclear Power
          • Nuclear Power
          • Personnel Exposure
          • Access Control
          • Workplace Safety
          • Calibration and Verification Equipment
        • Medical
          • Medical
          • Personnel Exposure
          • Radiation Area Monitoring
          • Waste control
        • Homeland Security
          • Homeland Security
          • Radiation Security of Public Events & Sites
          • Emergency Response
          • Illicit Trafficking of Nuclear and Radioactive Materials
        • Oil & Gas | Mining
          • Oil & Gas | Mining
          • Exploration Geology
          • Soil Inspection
          • Inspection of Raw Materials, Waste & Goods
          • Surface Contamination
          • Radiation Safety in NDT
        • Industrial Safety
          • Industrial Safety
          • Personnel Exposure
          • Internal Control of IR sources
          • Inspection of Raw Materials, Waste & Goods
          • Laboratory Equipment
      • Services
        • Services
        • Design and development
        • Commissioning
        • Trainings
        • Maintenance
      • Company
        • Company
        • About Us
        • Company details
        • Certificates
        • News
        • Articles
      • Dealers
      • Support
      • Contacts
      • EN
        • Website
        • EN
        • RU
      • info@radmetron.com

      Radiation Portal Monitors

      Radmetron | Main
      —
      Products
      —Radiation Portal Monitors
      Transport RPMs
      9 products
      Pedestrian & Luggage RPMs
      4 products
      Filter
      By popularity (descending)
      By name (A-Z)
      By name (Z-A)
      By popularity (ascending)
      By popularity (descending)
      Установка радиационного контроля УРК-PM5000B-10 Установка радиационного контроля УРК-PM5000B-10 Установка радиационного контроля УРК-PM5000B-10 Установка радиационного контроля УРК-PM5000B-10 Установка радиационного контроля УРК-PM5000B-10
      Transport RPMs
      Radiation Monitor PM5000B-10
      On order

      Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.

      Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.


      Type of registered radiation — gamma, neutron
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 4.5 m —
        8 km/h 20 km/h
      241Am, MBq, (µCi) 1.5 (41) 2.3 (62)
      137Cs, MBq, (µCi) 0.16 (4.3) 0.24 (6.5)
      60Co, MBq, (µCi) 0.10 (2.7) 0.15 (4.1)
       57Co, MBq, (µCi) 0.20 (5.4) 0.30 (8.1)
      133Ba, MBq, (µCi) 0.10 (2.7) 0.15 (4.1)
      238U, g 1300 1900
      235U, g 80 120
      239Pu,g 2.3 3.4
      239Pu, g (4 cm Pb)
      240
      400
      252Cf, neutron/s
      14000
      24000
      Number of detection units — 8 detectors
      Weight — one gamma detector – 120 kg; one neutron detector - 130 kg; control unit - 20 kg
      Ingress protection — IP65
      Mean recovery time — no more then 60 min
      Mean service lifetime — no less then 8 years
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — -30 up to +50°C
      Humidity — up to 98 % at 40°C and lower, no moisture
      Power source —
      industrial AC network (115-230V range) 47/63 Hz frequency
      built-in accumulator battery 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours).
      Power consumption —
      no more then 120 V•А.
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000P-03B
      Pedestrian & Luggage RPMs
      Radiation monitor PM5000P-03B
      On order

      Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.

      Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.


      Type of registered radiation — gamma-neutron
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1 x 2 m —
      241Am, MBq, (µCi) 0.2 (5.5)
      137Cs, MBq, (µCi) 0.032 (0.87)
      60Co, MBq, (µCi) 0.018 (0.47)
      133Ba MBq, (µCi) 0.02 (0.55)
      238U, g 250
      235U, g 13.4
      239Pu, g 0.4
      239Pu, g (4 cm Pb) 42
      252Cf, neutron/s 2500
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 2 m —
      241Am, MBq, (µCi) 0.32 (8.7)
      137Cs, MBq, (µCi) 0.048 (1.3)
      60Co, MBq, (µCi) 0.026 (0.71)
      133Ba MBq, (µCi) 0.03 (0.8)
      238U, g 380
      235U, g 20
      239Pu, g 0.6
      239Pu, g (4 cm Pb) 62
      252Cf, neutron/s 3700
      Number of detection units — 2
      Alarm Type — light, audio
      PC communication — Ethernet port by means of a cable up to 100 m in length
      Maximum speed, km/h — 5
      Weight — 265 kg
      Mean recovery time — no more than 60 min
      Mean service lifetime — no less than 8 years
      Atmospheric pressure — from 84 to 106,7 kPa
      Operating temperature — -30... + 50 °C
      Humidity — up to 98% at 40 °C and colder, no moisture
      Power source —
      industrial AC network (from 85 to 264 V range) with from 47 to 63 Hz frequency
      built-in accumulator battery 12 V DC (back-up)
      Power consumption — no more than    60 VА
      Battery Lifetime —
      Accumulator battery continuous working of the monitor during 8 hours
      Order
      Ask a Question
      New
      Установка радиационного контроля УРК-РМ5000КМ-02
      Transport RPMs
      Radiation monitor PM5000KM-02
      On order

      Radiation Portal Monitors PM5000KM series are highly sensitive fixed-installation systems designed to control transport and luggage at stationary checkpoints for preventing illicit trafficking of radioactive materials.

      Energy range of the measures of photon radiation — 60 keV - 3 MeV
      Ambient dose equivalent rate (ADER) of photon radiation measurement range — 0.1 - 30 μSv/h (for energy 662 keV)
      Accuracy of photon radiation ADER measurement — ±30 %
      False alarm rate — 1/1000
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 5 km/h
      133Ba - 40 kBq
      137Cs - 50 kBq
       60Co - 24 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 15 km/h
      133Ba - 165 kBq
      137Cs - 200 kBq
       60Co - 95 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3.5 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,25 μSv/h
      when source is shielded with 1 mm of steel
      at source speed 10 km/h
      133Ba - 340 kBq
      137Cs - 410 kBq
       60Co - 210 kBq
      in long-dwell scan mode
      133Ba - 60 kBq
      137Cs - 70 kBq
       60Co - 35 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 15 km/h
      133Ba - 315 kBq
      137Cs - 390 kBq
       60Co - 190 kBq
      in long-dwell scan mode
      133Ba - 53 kBq
      137Cs - 67 kBq
       60Co - 32 kBq
      Number of detection units — 2
      PC communication — Ethernet, WiFi
      Ingress protection — IP65
      Mean recovery time — no more then 60 min
      Mean service lifetime — 15 years
      Mean time between failyres, no less than — 20 000 h
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — -30 up to +50 °C
      -50 up to +50 °C with heating module
      Humidity — 98 %  at +40 °С and lower temperature
      Power source — AC mains, built-in accumulator
      Supply voltage — 90 - 132 V or 180 - 264 V, 47 - 63 Hz
      Power consumption — no more then 80 V⋅A (without video surveillance and heating)
      no more then 940 V⋅A (with video surveillance and heating)
      Battery Lifetime — 3 h
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000P
      Pedestrian & Luggage RPMs
      Radiation monitor PM5000P
      On order

      Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.

      Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.

      Type of registered radiation — gamma
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1 x 2 m —
      241Am, MBq, (µCi) 0.4 (11)
      137Cs, MBq, (µCi) 0.08 (2)
      60Co, MBq, (µCi) 0.04 (1.1)
      133Ba MBq, (µCi) 0.05 (1.25)
      238U, g 470
      235U, g 30
      239Pu, g 0.8
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 2 m —
      241Am, MBq, (µCi) 0.7 (19)
      137Cs, MBq, (µCi) 0.13 (3.5)
      60Co, MBq, (µCi) 0.07 (1.9)
      133Ba MBq, (µCi) 0.08 (2.16)
      238U, g 815
      235U, g 50
      239Pu, g 1.4
      Number of detection units — 1
      Alarm Type — light, audio
      PC communication — Ethernet port by means of a cable up to 100 m in length
      Maximum speed, km/h — 5
      Weight — 125 kg
      Ingress protection — IP65
      Mean recovery time — no more than 60 min
      Mean service lifetime — no less than 8 years
      Atmospheric pressure — from 84 to 106,7 kPa
      Operating temperature — -30... + 50 °C
      Humidity — up to 98% at 40 °C and colder, no moisture
      Power source —
      industrial AC network (from 85 to 264 V range) with from 47 to 63 Hz frequency
      built-in accumulator battery 12 V DC (back-up)
      Power consumption —
      no more than 60 VА
      Battery Lifetime —
      Accumulator battery continuous working of the monitor during 8 hours
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000P-01
      Pedestrian & Luggage RPMs
      Radiation monitor PM5000P-01
      On order

      Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.

      Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.

      Type of registered radiation — gamma
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1 x 2 m —
      241Am, MBq, (µCi) 0.12 (3.2)
      137Cs, MBq, (µCi) 0.022 (0.59)
      60Co, MBq, (µCi) 0.012 (0.32)
      133Ba MBq, (µCi) 0.013 (0.36)
      238U, g 140
      235U, g 8.5
      239Pu, g 0.24

      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 2 m —
      241Am, MBq, (µCi) 0.175 (4.75)
      137Cs, MBq, (µCi) 0.033 (0.88)
      60Co, MBq, (µCi) 0.0175 (0.475)
      133Ba MBq, (µCi) 0.02 (0.54)
      238U, g 205
      235U, g 12.5
      239Pu, g 0.36
      Number of detection units — 2
      Alarm Type — light, audio
      PC communication — Ethernet port by means of a cable up to 100 m in length
      Maximum speed, km/h — 5
      Weight — 245 kg
      Ingress protection — IP65
      Mean recovery time — no more than 60 min
      Mean service lifetime — no less than 8 years
      Atmospheric pressure — from 84 to 106,7 kPa
      Operating temperature — -30... + 50 °C
      Humidity — up to 98% at 40 °C and colder, no moisture
      Power source —
      industrial AC network (from 85 to 264 V range) with from 47 to 63 Hz frequency
      built-in accumulator battery 12 V DC (back-up)
      Power consumption —
      no more than 60 VА
      Battery Lifetime —
      Accumulator battery continuous working of the monitor during 8 hours
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000P-02B
      Pedestrian & Luggage RPMs
      Radiation monitor PM5000P-02B
      On order

      Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.

      Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.


      Type of registered radiation — gamma-neutron
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1 x 2 m —
      241Am, MBq, (µCi) 0.75 (20)
      137Cs, MBq, (µCi) 0.12 (3.2)
      60Co, MBq, (µCi) 0.65 (1.8)
      133Ba MBq, (µCi) 0.075 (2)
      238U, g 870
      235U, g 47
      239Pu, g 1.4
      239Pu, g (4 cm Pb) 110
      252Cf, neutron/s 6500
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 2 m —
      241Am, MBq, (µCi) 1.29 (35)
      137Cs, MBq, (µCi) 0.21 (5.6)
      60Co, MBq, (µCi) 0.11 (3)
      133Ba MBq, (µCi) 0.13 (3.5)
      238U, g 1500
      235U, g 80
      239Pu, g 2.3
      239Pu, g (4 cm Pb) 190
      252Cf, neutron/s 11250
      Number of detection units — 1
      Alarm Type — light, audio
      PC communication — Ethernet port by means of a cable up to 100 m in length
      Maximum speed, km/h — 5
      Weight — 135 kg
      Ingress protection — IP65
      Mean recovery time — no more than 60 min
      Mean service lifetime — no less than 8 years
      Atmospheric pressure — from 84 to 106,7 kPa
      Operating temperature — -30... + 50 °C
      Humidity — up to 98% at 40 °C and colder, no moisture
      Power source —
      industrial AC network (from 85 to 264 V range) with from 47 to 63 Hz frequency
      built-in accumulator battery 12 V DC (back-up)
      Power consumption —
      no more than 60 VА
      Battery Lifetime —
      Accumulator battery continuous working of the monitor during 8 hours
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000B-05 Установка радиационного контроля УРК-PM5000B-05 Установка радиационного контроля УРК-PM5000B-05 Установка радиационного контроля УРК-PM5000B-05 Установка радиационного контроля УРК-PM5000B-05
      Transport RPMs
      Radiation Monitor PM5000B-05
      On order

      Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.

      Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.

      Type of registered radiation — gamma
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 2 m —
        5 km/h
      241Am, MBq, (µCi) 0.62 (17)
      137Cs, MBq, (µCi) 0.065 (1.8)
      60Co, MBq, (µCi) 0.040 (1.1)
      57Co, MBq (µCi) 0.085 (2.3)
      133Ba, MBq (µCi) 0.040 (1.1)
      238U, g 460
      235U, g 32
      239Pu,g 0.9
      Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 2 m —
      241Am, MBq, (µCi); speed 8 km/h. 2.15 (58)
      137Cs, MBq, (µCi); speed 8 km/h. 0.23 (6.2)
      60Co, MBq, (µCi); speed 8 km/h. 0.145 (3.9)
      57Co, MBq (µCi); speed 8 km/h. 0.29 (7.8)
      133Ba, MBq (µCi); speed 8 km/h. 0.145 (3.9)
      238U, g; speed 8 km/h. 1800
      235U, g; speed 8 km/h. 110
      239Pu,g; speed 8 km/h. 3.2
      Number of detection units — 2 detectors
      Weight — one gamma detector – 120 kg; control unit - 20 kg
      Ingress protection — IP65
      Mean recovery time — no more then 60 min
      Mean service lifetime — no less then 8 years
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — -30 up to +50°C
      Humidity — up to 98 % at 40°C and lower, no moisture
      Power source —
      industrial AC network (115-230V range) 47/63 Hz frequency
      built-in accumulator battery 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours).
      Power consumption —
      no more then 120 V•А.
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000B-09 Установка радиационного контроля УРК-PM5000B-09 Установка радиационного контроля УРК-PM5000B-09 Установка радиационного контроля УРК-PM5000B-09 Установка радиационного контроля УРК-PM5000B-09
      Transport RPMs
      Radiation Monitor PM5000B-09
      On order

      Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.

      Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.

      Type of registered radiation — gamma, neutron
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 2 m —
        5 km/h
      241Am, MBq, (µCi) 0.62 (17)
      137Cs, MBq, (µCi) 0.065 (1.8)
      60Co, MBq (µCi) 0.040 (1.1)
      57Co, MBq, (µCi) 0.085 (2.3)
      133Ba, MBq (µCi) 0.040 (1.1)
      238U, g 460
      235U, g 32
      239Pu,g 0.9
      239Pu,g (4 cm Pb) 110
      252Cf, neutron/s 6500
      Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 2 m —
        8 km/h
      241Am, MBq, (µCi) 2.15 (58)
      137Cs, MBq, (µCi) 0.23 (6.2)
      60Co, MBq (µCi) 0.145 (3.9)
      57Co, MBq, (µCi)  0.29 (7.8)
      133Ba, MBq (µCi) 0.145 (3.9)
      238U, g 1800
      235U, g 110
      239Pu,g 3.2
      239Pu,g (4 cm Pb) 340
      252Cf, neutron/s 20000
      Number of detection units — 4 detectors
      Weight — one gamma detector – 120 kg; one neutron detector - 130 kg; control unit - 20 kg
      Ingress protection — IP65
      Mean recovery time — no more then 60 min
      Mean service lifetime — no less then 8 years
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — -30 up to +50°C
      Humidity — up to 100 % at 35°C and lower, no moisture
      Power source —
      industrial AC network (115-230V range) 47/63 Hz frequency
      built-in accumulator battery 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours).
      Power consumption —
      no more then 120 V•А.
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000B-01 Установка радиационного контроля УРК-PM5000B-01 Установка радиационного контроля УРК-PM5000B-01 Установка радиационного контроля УРК-PM5000B-01 Установка радиационного контроля УРК-PM5000B-01
      Transport RPMs
      Radiation Monitor PM5000B-01
      On order

      Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.

      Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites,  scrap metal industry, governmental offices, banks and post offices.


      Type of registered radiation — gamma
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 4.5 m —
          8 km/h   20 km/h
      241Am, MBq, (µCi)   1.5 (41) 2.3 (62)
      137Cs, MBq, (µCi)   0.16 (4.3) 0.24 (6.5)
      60Co, MBq, (µCi)   0.16 (4.3) 0.15 (4.1)
      57Co, MBq (µCi)   0.20 (5.4) 0.30 (8.1)
      133Ba, MBq (µCi)   0.10 (2.7)  0.15 (4.1)
      238U, g   1300 1900
      235U, g   80 120
      239Pu,g   2.3 3.4
      Number of detection units — 4 detectors
      Weight — one gamma detector – 120 kg; control unit - 20 kg
      Ingress protection — IP65
      Mean recovery time — no more then 60 min
      Mean service lifetime — no less then 8 years
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — -30 up to +50°C
      Humidity — up to 98 % at 40°C and lower, no moisture
      Power source —
      industrial AC network (115-230V range) 47/63 Hz frequency
      built-in accumulator battery 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours).
      Power consumption —
      no more then 120 V•А.
      Order
      Ask a Question
      New
      Установка радиационного контроля УРК-РМ5000КМ-01 Установка радиационного контроля УРК-РМ5000КМ-01
      Transport RPMs
      On order
      Radiation Portal Monitors PM5000KM series are highly sensitive fixed-installation systems designed to control transport and luggage at stationary checkpoints for preventing illicit trafficking of radioactive materials.
      Energy range of the measures of photon radiation — 60 keV - 3 MeV
      Ambient dose equivalent rate (ADER) of photon radiation measurement range — 0.1 - 30 μSv/h (for energy 662 keV)
      Accuracy of photon radiation ADER measurement — ±30 %
      False alarm rate — 1/1000
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 5 km/h
      133Ba - 135 kBq
      137Cs - 150 kBq
      60Co - 78 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 15 km/h
      133Ba - 610 kBq
      137Cs - 670  kBq
      60Co - 350 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3.5 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,25 μSv/h
      when source is shielded with 1 mm of steel
      at source speed 10 km/h
      133Ba - 1060 kBq
      137Cs - 1170 kBq
      60Co - 610 kBq
      in long-dwell scan mode
      133Ba - 185 kBq
      137Cs - 205 kBq
      60Co - 105 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 15 km/h
      133Ba - 1350 kBq
      137Cs - 1470 kBq
      60Co - 760 kBq
      in long-dwell scan mode
      133Ba - 230 kBq
      137Cs - 250 kBq
      60Co - 135 kBq
      Number of detection units — 1
      PC communication — Ethernet, WiFi
      Ingress protection — IP65
      Mean recovery time — no more then 60 min
      Mean service lifetime — 15 years
      Mean time between failyres, no less than — 20 000 h
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — -30 up to +50 °C
      -50 up to +50 °C with heating module
      Humidity — 98 %  at +40 °С and lower temperature
      Power source — AC mains, built-in accumulator
      Supply voltage — 90 - 132 V or 180 - 264 V, 47 - 63 Hz
      Power consumption — no more then 60 V⋅A (without video surveillance and heating)
      no more then 520 V⋅A (with video surveillance and heating)
      Battery Lifetime — 6 h
      Order
      Ask a Question
      Show more
      1 2
      Catalog
      • Dosimeters
        • Electronic Dosimeters
        • Personal Dosimeters
      • Personal Radiation Detectors
        • Gamma-Neutron PRDs
        • Gamma PRDs
      • Radiation Portal Monitors
        • Transport RPMs
        • Pedestrian & Luggage RPMs
      • Radionuclide Identification Devices
      • Smart Probes
      • Contamination Measurement Radiometers
      • Contraband Detector
      • Chemical Agent Detection Equipment
      • Radiation Monitoring System
      • Gamma and Neutron Radiation Calibration Equipment
      • System Software
      Your key to radiation safety!
      Catalog
      Company
      Contacts
      Company details
      +375 (17) 336 68 68
      +375 (17) 336 68 68 Phone
      +375 (44) 773 44 44 Phone
      E-mail
      info@radmetron.com
      info@radmetron.com
      © 2025 Radmetron Ltd.
      All rigts reserved 
      ISO 9001 Certified
      ISO 9001 Certified
      Website Terms of Use and Personal Data Processing Policy
      A Cookie Policy
      Withdrawal of consent to the processing of personal data