Radiation monitor PM5000KM-02
New
Radiation Portal Monitors PM5000KM series are highly sensitive fixed-installation systems designed to control transport and luggage at stationary checkpoints for preventing illicit trafficking of radioactive materials.
Characteristics
Energy range of the measures of photon radiation
—
60 keV - 3 MeV
Ambient dose equivalent rate (ADER) of photon radiation measurement range
—
0.1 - 30 μSv/h (for energy 662 keV)
Accuracy of photon radiation ADER measurement
—
±30 %
False alarm rate
—
1/1000
Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 3 m
—
with 0.5 probability and at least 0.95 confidence probability
at gamma radiation background 0,1 μSv/h
at source speed 5 km/h
133Ba - 40 kBq
137Cs - 50 kBq
60Co - 24 kBq
at gamma radiation background 0,1 μSv/h
at source speed 5 km/h
133Ba - 40 kBq
137Cs - 50 kBq
60Co - 24 kBq
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3 m
—
with 0.5 probability and at least 0.95 confidence probability
at gamma radiation background 0,1 μSv/h
at source speed 15 km/h
133Ba - 165 kBq
137Cs - 200 kBq
60Co - 95 kBq
at gamma radiation background 0,1 μSv/h
at source speed 15 km/h
133Ba - 165 kBq
137Cs - 200 kBq
60Co - 95 kBq
Radiation monitor PM5000KM-02
Operation modes
- detection mode
- long-dwell scan mode
- dose equivalent rate measurement mode
Features
- high sensitivity
- ease of installation
- audible and light alarms and an optional remote annunciator
- video surveillance (optional)
- PC connection via Ethernet of WiFi
- 24/7 operation with the history recording
- suitable for use in harsh environment
Application
- mining, petrochemical and metallurgical industry
- industrial and cargo stationary customs checkpoints
- scrap metal industry
- radioactive waste disposal and storage sites
- NPPs and nuclear industry enterprises
Characteristics
Energy range of the measures of photon radiation
|
60 keV - 3 MeV |
Ambient dose equivalent rate (ADER) of photon radiation measurement range
|
0.1 - 30 μSv/h (for energy 662 keV) |
Accuracy of photon radiation ADER measurement
|
±30 % |
False alarm rate
|
1/1000 |
Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability at gamma radiation background 0,1 μSv/h at source speed 5 km/h 133Ba - 40 kBq 137Cs - 50 kBq 60Co - 24 kBq |
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability at gamma radiation background 0,1 μSv/h at source speed 15 km/h 133Ba - 165 kBq 137Cs - 200 kBq 60Co - 95 kBq |
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3.5 m
|
with 0.5 probability and at least 0.95 confidence probability at gamma radiation background 0,25 μSv/h when source is shielded with 1 mm of steel at source speed 10 km/h 133Ba - 340 kBq 137Cs - 410 kBq 60Co - 210 kBq in long-dwell scan mode 133Ba - 60 kBq 137Cs - 70 kBq 60Co - 35 kBq |
Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability at gamma radiation background 0,1 μSv/h at source speed 15 km/h 133Ba - 315 kBq 137Cs - 390 kBq 60Co - 190 kBq in long-dwell scan mode 133Ba - 53 kBq 137Cs - 67 kBq 60Co - 32 kBq |
Number of detection units
|
2 |
PC communication
|
Ethernet, WiFi |
Ingress protection
|
IP65 |
Mean recovery time
|
no more then 60 min |
Mean service lifetime
|
15 years |
Mean time between failyres, no less than
|
20 000 h |
Atmospheric pressure
|
from 84 to 106.7 kPa |
Operating temperature
|
-30 up to +50 °C -50 up to +50 °C with heating module |
Humidity
|
98 % at +40 °С and lower temperature |
Power source
|
AC mains, built-in accumulator |
Supply voltage
|
90 - 132 V or 180 - 264 V, 47 - 63 Hz |
Power consumption
|
no more then 80 V⋅A (without video surveillance and heating) no more then 940 V⋅A (with video surveillance and heating) |
Battery Lifetime
|
3 h |
Advertising:
Advertising Leaflet