PM1621 series dosimeters are professional energy-compensated instruments, designed to monitor and measure dose equivalent and dose equivalent rate from both gamma and X-ray radiation. Instruments are highly sensitive and register the slightest changes in the natural background radiation. Hermetic and shockproof case and fluorescent backlight on LCD screen allow operation in the harsh and unfavorable environments. PM1621MA modification has searching algorithm for detection and localization of radioactive materials, extended DER measurement range and integrated vibro and light alarm.
Instruments of PM1621 series are recommended to use by Law Enforcement and Security agencies, scientists, medical and other professionals, exposed to gamma and X-ray radiation.
DER not more than 0.3 µSv/h, alarms activated for not more than 20 s/24 hours | 12 months (at a t from 0 up to 60°С) |
PM1621 series dosimeters are professional energy-compensated instruments, designed to monitor and measure dose equivalent and dose equivalent rate from both gamma and X-ray radiation. Instruments are highly sensitive and register the slightest changes in the natural background radiation. Hermetic and shockproof case and fluorescent backlight on LCD screen allow operation in the harsh and unfavorable environments. PM1621M modification has searching algorithm for detection and localization of radioactive materials.
Instruments of PM1621 series are recommended to use by Law Enforcement and Security agencies, scientists, medical and other professionals, exposed to gamma and X-ray radiation.
DER not more than 0.3 µSv/h, alarms activated for not more than 20 s/24 hours | 12 months (at a t from 0 up to 60°С) |
PM1621 series dosimeters are professional energy-compensated instruments, designed to monitor and measure dose equivalent and dose equivalent rate from both gamma and X-ray radiation. Instruments are highly sensitive and register the slightest changes in the natural background radiation. Hermetic and shockproof case and fluorescent backlight on LCD screen allow operation in the harsh and unfavorable environments.
Instruments of PM1621 series are recommended to use by Law Enforcement and Security agencies, scientists, medical and other professionals, exposed to gamma and X-ray radiation.
DER not more than 0.3 µSv/h, alarms activated for not more than 20 s/24 hours | 12 months (at a t from 0 up to 60°С) |
PM1621 series dosimeters are professional energy-compensated instruments, designed to monitor and measure dose equivalent and dose equivalent rate from both gamma and X-ray radiation. Instruments are highly sensitive and register the slightest changes in the natural background radiation. Hermetic and shockproof case and fluorescent backlight on LCD screen allow operation in the harsh and unfavorable environments.
Instruments of PM1621 series are recommended to use by Law Enforcement and Security agencies, scientists, medical and other professionals, exposed to gamma and X-ray radiation.
DER not more than 0.3 µSv/h, alarms activated for not more than 20 s/24 hours | 12 months (at a t from 0 up to 60°С) |
real-time control of radiation situation and measurement of
personnel exposure. Device is an excellent instrument for
personnel, exposed to pulsed X-ray and gamma radiation.
−40 to +29 % for energy range 33 keV - 48 keV
±29 % for energy range 48 keV - 3 MeV
±50 % for energy range 3 MeV - 10 MeV
Dosimeters perform monitoring and measurement of dose equivalent and dose equivalent rate in the wide energy range - from 1 mSv/h up to 5.00 Sv/h (for PM1603A) and from 1 mSv/h up to 10.0 Sv/h (for PM1603B). Instruments have two thresholds in DER and DE ranges and non-volatile memory for data storage. Hermetic, water-resistant and shockproof case and the fluorescent backlight on LCD screen allow to use instruments in harsh and extreme conditions.
PM1603A and PM1603B dosimeters are recommended for emergency services, customs and border patrol, radiological and radioisotope laboratories, medical professionals, personnel of nuclear facilities, civil defense, firefighters and police.
using LCD backlight not more than 5 s/day, audible alarm – not more than 20 s/day and at an average value of the measured DER up to 0.3 μSv/h, at least | 9 months |
Dosimeters perform monitoring and measurement of dose equivalent and dose equivalent rate in the wide energy range - from 1 mSv/h up to 5.00 Sv/h (for PM1603A) and from 1 mSv/h up to 10.0 Sv/h (for PM1603B). Instruments have two thresholds in DER and DE ranges and non-volatile memory for data storage. Hermetic, water-resistant and shockproof case and the fluorescent backlight on LCD screen allow to use instruments in harsh and extreme conditions.
PM1603A and PM1603B dosimeters are recommended for emergency services, customs and border patrol, radiological and radioisotope laboratories, medical professionals, personnel of nuclear facilities, civil defense, firefighters and police.
using LCD backlight not more than 5 s/day, audible alarm – not more than 20 s/day and at an average value of the measured DER up to 0.3 μSv/h, at least | 9 months |
Spectroscopic Radiation Monitor PM1403 is designed for measurement of ADER of gamma radiation, searching for radioactive sources, registration and accumulation of scintillation spectra and radionuclide identification. External smart probes and built-in Csl(TI) detector make PM1403 a powerful tool for detection and localization of gamma, neutron, alpha and beta radiation sources. Instrument has built-in GPS/GLONASS, GSM/GPRS, Bluetooth® 2.0. modules for data exchange. Non-volatile memory enables saving accumulated scintillation spectra.
Instrument is recommended to first responders, customs and border patrol, police, emergency teams, law enforcement, hazmat teams, security guards.
133Ba - 55 kBq
137Cs - 100 kBq
60Co - 50 kBq
- without GPRS and WiFi usage
- without usage of external detectors
8 h on condition:
- without GPRS and WiFi usage
- with external detector
Radiation Monitoring System PM520 is designed for continuous gamma and neutron radiation monitoring of different facilities where radioactive sources are stored or processed.
PM520 can be deployed in several separate locations or in passageways outdoors. Apart from other systems, PM520 has flexible configuration and uses up to 8 wall-mounted Gamma and Neutron Probes of different sensitivities and measurement ranges, main processing unit and remote PC for operation monitoring control with maximum distance between probes and unit up 1000 m. This configuration allows extending the range of controlled area with possibility of transferring measurement data to the single coordination center.
Radiation Monitoring System can be used in different areas: nuclear facilities, waste management, areas and buildings with limited access, border/airport check points, places of storage and use of nuclear materials.
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.2 (5.5) |
137Cs, MBq, (µCi) | 0.032 (0.87) |
60Co, MBq, (µCi) | 0.018 (0.47) |
133Ba MBq, (µCi) | 0.02 (0.55) |
238U, g | 250 |
235U, g | 13.4 |
239Pu, g | 0.4 |
239Pu, g (4 cm Pb) | 42 |
252Cf, neutron/s | 2500 |
241Am, MBq, (µCi) | 0.32 (8.7) |
137Cs, MBq, (µCi) | 0.048 (1.3) |
60Co, MBq, (µCi) | 0.026 (0.71) |
133Ba MBq, (µCi) | 0.03 (0.8) |
238U, g | 380 |
235U, g | 20 |
239Pu, g | 0.6 |
239Pu, g (4 cm Pb) | 62 |
252Cf, neutron/s | 3700 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.75 (20) |
137Cs, MBq, (µCi) | 0.12 (3.2) |
60Co, MBq, (µCi) | 0.65 (1.8) |
133Ba MBq, (µCi) | 0.075 (2) |
238U, g | 870 |
235U, g | 47 |
239Pu, g | 1.4 |
239Pu, g (4 cm Pb) | 110 |
252Cf, neutron/s | 6500 |
241Am, MBq, (µCi) | 1.29 (35) |
137Cs, MBq, (µCi) | 0.21 (5.6) |
60Co, MBq, (µCi) | 0.11 (3) |
133Ba MBq, (µCi) | 0.13 (3.5) |
238U, g | 1500 |
235U, g | 80 |
239Pu, g | 2.3 |
239Pu, g (4 cm Pb) | 190 |
252Cf, neutron/s | 11250 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.12 (3.2) |
137Cs, MBq, (µCi) | 0.022 (0.59) |
60Co, MBq, (µCi) | 0.012 (0.32) |
133Ba MBq, (µCi) | 0.013 (0.36) |
238U, g | 140 |
235U, g | 8.5 |
239Pu, g | 0.24 |
241Am, MBq, (µCi) | 0.175 (4.75) |
137Cs, MBq, (µCi) | 0.033 (0.88) |
60Co, MBq, (µCi) | 0.0175 (0.475) |
133Ba MBq, (µCi) | 0.02 (0.54) |
238U, g | 205 |
235U, g | 12.5 |
239Pu, g | 0.36 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |