PM1401K-3 is the smallest and the most lightweight instrument in the world, which is capable to operate simultaneously as an alarming device, search instrument, survey meter, spectrometer and identifier.
The instrument can be used both indoors and outdoors and is intended for everyday and/or emergency use by officers of radiological and isotope laboratories, specialists of different industries, agriculture, transport, medicine, customs and border services, firefighters, military, police and other first responding agencies.
where φα - measured α-radiation flux densty, min-1⋅cm-2
where φβ - measured β-radiation flux densty, min-1⋅cm-2
where А - measured activity concentrations, Bq/kg (Bq/l)
±30 % for energy range 45 keV - 15 MeV
at a distance of 0.2 m when moving at a speed of 0.5 m/s
133Ba - 55 kBq
137Cs - 100 kBq
60Co - 50 kBq
standard sample of plutonium - 0,3 г
standard sample of uranium - 10 г
neutron radiation sources
at a distance of 1 m when moving at a speed of 0.5 m/s
252Cf - 15 000 n/s
standard sample of plutonium - 250 г
ADER up to 0,3 μSv/h,
backlight usage up to 5 min/day,
alarm duration up to 5 min/day
ANSI N42.42-2012, ANSI N42.48-2008,
IEC 62327:2006
Display and control unit cannot be used independently since it is designed to display information when operates together with the external smart probes, to program its operation modes and to identify radionuclide composition.
The instrument indicates the menu and measurement results, stores the accumulated scintillation spectra in its permanent memory, enables communication with PC as well as receives GPS information and transfers data via USB and Bluetooth interfaces.
Radiation Monitoring System PM520 is designed for continuous gamma and neutron radiation monitoring of different facilities where radioactive sources are stored or processed.
PM520 can be deployed in several separate locations or in passageways outdoors. Apart from other systems, PM520 has flexible configuration and uses up to 8 wall-mounted Gamma and Neutron Probes of different sensitivities and measurement ranges, main processing unit and remote PC for operation monitoring control with maximum distance between probes and unit up 1000 m. This configuration allows extending the range of controlled area with possibility of transferring measurement data to the single coordination center.
Radiation Monitoring System can be used in different areas: nuclear facilities, waste management, areas and buildings with limited access, border/airport check points, places of storage and use of nuclear materials.
Spectroscopic Radiation Monitor PM1403 is designed for measurement of ADER of gamma radiation, searching for radioactive sources, registration and accumulation of scintillation spectra and radionuclide identification. External smart probes and built-in Csl(TI) detector make PM1403 a powerful tool for detection and localization of gamma, neutron, alpha and beta radiation sources. Instrument has built-in GPS/GLONASS, GSM/GPRS, Bluetooth® 2.0. modules for data exchange. Non-volatile memory enables saving accumulated scintillation spectra.
Instrument is recommended to first responders, customs and border patrol, police, emergency teams, law enforcement, hazmat teams, security guards.
133Ba - 55 kBq
137Cs - 100 kBq
60Co - 50 kBq
- without GPRS and WiFi usage
- without usage of external detectors
8 h on condition:
- without GPRS and WiFi usage
- with external detector
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
8 km/h | 20 km/h | |
241Am, MBq, (µCi) | 1.5 (41) | 2.3 (62) |
137Cs, MBq, (µCi) | 0.16 (4.3) | 0.24 (6.5) |
60Co, MBq, (µCi) | 0.10 (2.7) | 0.15 (4.1) |
57Co, MBq, (µCi) | 0.20 (5.4) | 0.30 (8.1) |
133Ba, MBq, (µCi) | 0.10 (2.7) | 0.15 (4.1) |
238U, g | 1300 | 1900 |
235U, g | 80 | 120 |
239Pu,g | 2.3 | 3.4 |
239Pu, g (4 cm Pb) |
240 |
400 |
252Cf, neutron/s |
14000 |
24000 |
industrial AC network (115-230V range) | 47/63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours). |
no more then | 120 V•А. |
Neutron radiation detector BDN performs the following functions: measurement of DER of neutron radiation in collimated radiation by Pu- α -Be, search and registration of neutron radiation sources.
BDN can be used by radiological and isotope tracing laboratories, customs officers, emergency services to search and detect neutron radiation sources and to continuously monitor radiation environment.
for Pu-α-Be | 0.65 impulses·cm2 |
for thermal neutrons | 4.5 impulses·cm2 |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.2 (5.5) |
137Cs, MBq, (µCi) | 0.032 (0.87) |
60Co, MBq, (µCi) | 0.018 (0.47) |
133Ba MBq, (µCi) | 0.02 (0.55) |
238U, g | 250 |
235U, g | 13.4 |
239Pu, g | 0.4 |
239Pu, g (4 cm Pb) | 42 |
252Cf, neutron/s | 2500 |
241Am, MBq, (µCi) | 0.32 (8.7) |
137Cs, MBq, (µCi) | 0.048 (1.3) |
60Co, MBq, (µCi) | 0.026 (0.71) |
133Ba MBq, (µCi) | 0.03 (0.8) |
238U, g | 380 |
235U, g | 20 |
239Pu, g | 0.6 |
239Pu, g (4 cm Pb) | 62 |
252Cf, neutron/s | 3700 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
Accumulator battery | continuous working of the monitor during 8 hours |
Gamma radiation detector BDG3 performs the following functions: measurement of dose equivalent rate (DER) of X-ray and gamma radiation, search for the photon radiation sources, registration and accumulation of photon radiation scintillation spectra.
BDG3 can be used by emergency services, radiological and isotope laboratories, customs and border services, nuclear industry facilities, to search, detect and localize radioactive and nuclear sources and prevent illicit trafficking of radioactive and nuclear materials.
gamma-radiation scintillation spectra | 1024 |
for 137Cs in the search mode | 200.0 s-1/(μSv/h) |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.4 (11) |
137Cs, MBq, (µCi) | 0.08 (2) |
60Co, MBq, (µCi) | 0.04 (1.1) |
133Ba MBq, (µCi) | 0.05 (1.25) |
238U, g | 470 |
235U, g | 30 |
239Pu, g | 0.8 |
241Am, MBq, (µCi) | 0.7 (19) |
137Cs, MBq, (µCi) | 0.13 (3.5) |
60Co, MBq, (µCi) | 0.07 (1.9) |
133Ba MBq, (µCi) | 0.08 (2.16) |
238U, g | 815 |
235U, g | 50 |
239Pu, g | 1.4 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.12 (3.2) |
137Cs, MBq, (µCi) | 0.022 (0.59) |
60Co, MBq, (µCi) | 0.012 (0.32) |
133Ba MBq, (µCi) | 0.013 (0.36) |
238U, g | 140 |
235U, g | 8.5 |
239Pu, g | 0.24 |
241Am, MBq, (µCi) | 0.175 (4.75) |
137Cs, MBq, (µCi) | 0.033 (0.88) |
60Co, MBq, (µCi) | 0.0175 (0.475) |
133Ba MBq, (µCi) | 0.02 (0.54) |
238U, g | 205 |
235U, g | 12.5 |
239Pu, g | 0.36 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.75 (20) |
137Cs, MBq, (µCi) | 0.12 (3.2) |
60Co, MBq, (µCi) | 0.65 (1.8) |
133Ba MBq, (µCi) | 0.075 (2) |
238U, g | 870 |
235U, g | 47 |
239Pu, g | 1.4 |
239Pu, g (4 cm Pb) | 110 |
252Cf, neutron/s | 6500 |
241Am, MBq, (µCi) | 1.29 (35) |
137Cs, MBq, (µCi) | 0.21 (5.6) |
60Co, MBq, (µCi) | 0.11 (3) |
133Ba MBq, (µCi) | 0.13 (3.5) |
238U, g | 1500 |
235U, g | 80 |
239Pu, g | 2.3 |
239Pu, g (4 cm Pb) | 190 |
252Cf, neutron/s | 11250 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
5 km/h | |
241Am, MBq, (µCi) | 0.62 (17) |
137Cs, MBq, (µCi) | 0.065 (1.8) |
60Co, MBq, (µCi) | 0.040 (1.1) |
57Co, MBq (µCi) | 0.085 (2.3) |
133Ba, MBq (µCi) | 0.040 (1.1) |
238U, g | 460 |
235U, g | 32 |
239Pu,g | 0.9 |
241Am, MBq, (µCi); speed 8 km/h. | 2.15 (58) |
137Cs, MBq, (µCi); speed 8 km/h. | 0.23 (6.2) |
60Co, MBq, (µCi); speed 8 km/h. | 0.145 (3.9) |
57Co, MBq (µCi); speed 8 km/h. | 0.29 (7.8) |
133Ba, MBq (µCi); speed 8 km/h. | 0.145 (3.9) |
238U, g; speed 8 km/h. | 1800 |
235U, g; speed 8 km/h. | 110 |
239Pu,g; speed 8 km/h. | 3.2 |
industrial AC network (115-230V range) | 47/63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours). |
no more then | 120 V•А. |