Radmetron
+375 (17) 336 68 68
+375 (17) 336 68 68 Phone
+375 (44) 773 44 44 Phone
E-mail
info@radmetron.com
Catalog
  • Dosimeters
    • Electronic Dosimeters
    • Personal Dosimeters
  • Personal Radiation Detectors
    • Gamma-Neutron PRDs
    • Gamma PRDs
  • Radiation Portal Monitors
    • Transport RPMs
    • Pedestrian & Luggage RPMs
  • Radionuclide Identification Devices
  • Smart Probes
  • Contamination Measurement Radiometers
  • Contraband Detector
  • Chemical Agent Detection Equipment
  • Radiation Monitoring System
  • Gamma and Neutron Radiation Calibration Equipment
  • System Software
Applications
  • Nuclear Power
    • Personnel Exposure
    • Access Control
    • Workplace Safety
    • Calibration and Verification Equipment
  • Medical
    • Personnel Exposure
    • Radiation Area Monitoring
    • Waste control
  • Homeland Security
    • Radiation Security of Public Events & Sites
    • Emergency Response
    • Illicit Trafficking of Nuclear and Radioactive Materials
  • Oil & Gas | Mining
    • Exploration Geology
    • Soil Inspection
    • Inspection of Raw Materials, Waste & Goods
    • Surface Contamination
    • Radiation Safety in NDT
  • Industrial Safety
    • Personnel Exposure
    • Internal Control of IR sources
    • Inspection of Raw Materials, Waste & Goods
    • Laboratory Equipment
Services
  • Design and development
  • Commissioning
  • Trainings
  • Maintenance
Company
  • About Us
  • Company details
  • Certificates
  • News
  • Articles
Dealers
Support
Contacts
EN
RU
EN
+375 (17) 336 68 68
+375 (17) 336 68 68 Phone
+375 (44) 773 44 44 Phone
E-mail
info@radmetron.com
EN
RU
EN
Radmetron
Creation of innovative radiation control devices and systems to ensure human safety
Catalog
  • Dosimeters
    Dosimeters
    • Electronic Dosimeters
    • Personal Dosimeters
  • Personal Radiation Detectors
    Personal Radiation Detectors
    • Gamma-Neutron PRDs
    • Gamma PRDs
  • Radiation Portal Monitors
    Radiation Portal Monitors
    • Transport RPMs
    • Pedestrian & Luggage RPMs
  • Radionuclide Identification Devices
    Radionuclide Identification Devices
  • Smart Probes
    Smart Probes
  • Contamination Measurement Radiometers
    Contamination Measurement Radiometers
  • Contraband Detector
    Contraband Detector
  • Chemical Agent Detection Equipment
    Chemical Agent Detection Equipment
  • Radiation Monitoring System
    Radiation Monitoring System
  • Gamma and Neutron Radiation Calibration Equipment
    Gamma and Neutron Radiation Calibration Equipment
  • System Software
    System Software
Applications
  • Nuclear Power
    Nuclear Power
    • Personnel Exposure
    • Access Control
    • Workplace Safety
    • Calibration and Verification Equipment
  • Medical
    Medical
    • Personnel Exposure
    • Radiation Area Monitoring
    • Waste control
  • Homeland Security
    Homeland Security
    • Radiation Security of Public Events & Sites
    • Emergency Response
    • Illicit Trafficking of Nuclear and Radioactive Materials
  • Oil & Gas | Mining
    Oil & Gas | Mining
    • Exploration Geology
    • Soil Inspection
    • Inspection of Raw Materials, Waste & Goods
    • Surface Contamination
    • Radiation Safety in NDT
  • Industrial Safety
    Industrial Safety
    • Personnel Exposure
    • Internal Control of IR sources
    • Inspection of Raw Materials, Waste & Goods
    • Laboratory Equipment
Services
  • Design and development
  • Commissioning
  • Trainings
  • Maintenance
Company
  • About Us
  • Company details
  • Certificates
  • News
  • Articles
Dealers
Support
Contacts
    Radmetron
    Catalog
    • Dosimeters
      Dosimeters
      • Electronic Dosimeters
      • Personal Dosimeters
    • Personal Radiation Detectors
      Personal Radiation Detectors
      • Gamma-Neutron PRDs
      • Gamma PRDs
    • Radiation Portal Monitors
      Radiation Portal Monitors
      • Transport RPMs
      • Pedestrian & Luggage RPMs
    • Radionuclide Identification Devices
      Radionuclide Identification Devices
    • Smart Probes
      Smart Probes
    • Contamination Measurement Radiometers
      Contamination Measurement Radiometers
    • Contraband Detector
      Contraband Detector
    • Chemical Agent Detection Equipment
      Chemical Agent Detection Equipment
    • Radiation Monitoring System
      Radiation Monitoring System
    • Gamma and Neutron Radiation Calibration Equipment
      Gamma and Neutron Radiation Calibration Equipment
    • System Software
      System Software
    Applications
    • Nuclear Power
      Nuclear Power
      • Personnel Exposure
      • Access Control
      • Workplace Safety
      • Calibration and Verification Equipment
    • Medical
      Medical
      • Personnel Exposure
      • Radiation Area Monitoring
      • Waste control
    • Homeland Security
      Homeland Security
      • Radiation Security of Public Events & Sites
      • Emergency Response
      • Illicit Trafficking of Nuclear and Radioactive Materials
    • Oil & Gas | Mining
      Oil & Gas | Mining
      • Exploration Geology
      • Soil Inspection
      • Inspection of Raw Materials, Waste & Goods
      • Surface Contamination
      • Radiation Safety in NDT
    • Industrial Safety
      Industrial Safety
      • Personnel Exposure
      • Internal Control of IR sources
      • Inspection of Raw Materials, Waste & Goods
      • Laboratory Equipment
    Services
    • Design and development
    • Commissioning
    • Trainings
    • Maintenance
    Company
    • About Us
    • Company details
    • Certificates
    • News
    • Articles
    Dealers
    Support
    Contacts
      EN
      RU
      Radmetron
      Radmetron
      • Catalog
        • Catalog
        • Dosimeters
          • Dosimeters
          • Electronic Dosimeters
          • Personal Dosimeters
        • Personal Radiation Detectors
          • Personal Radiation Detectors
          • Gamma-Neutron PRDs
          • Gamma PRDs
        • Radiation Portal Monitors
          • Radiation Portal Monitors
          • Transport RPMs
          • Pedestrian & Luggage RPMs
        • Radionuclide Identification Devices
        • Smart Probes
        • Contamination Measurement Radiometers
        • Contraband Detector
        • Chemical Agent Detection Equipment
        • Radiation Monitoring System
        • Gamma and Neutron Radiation Calibration Equipment
        • System Software
      • Applications
        • Applications
        • Nuclear Power
          • Nuclear Power
          • Personnel Exposure
          • Access Control
          • Workplace Safety
          • Calibration and Verification Equipment
        • Medical
          • Medical
          • Personnel Exposure
          • Radiation Area Monitoring
          • Waste control
        • Homeland Security
          • Homeland Security
          • Radiation Security of Public Events & Sites
          • Emergency Response
          • Illicit Trafficking of Nuclear and Radioactive Materials
        • Oil & Gas | Mining
          • Oil & Gas | Mining
          • Exploration Geology
          • Soil Inspection
          • Inspection of Raw Materials, Waste & Goods
          • Surface Contamination
          • Radiation Safety in NDT
        • Industrial Safety
          • Industrial Safety
          • Personnel Exposure
          • Internal Control of IR sources
          • Inspection of Raw Materials, Waste & Goods
          • Laboratory Equipment
      • Services
        • Services
        • Design and development
        • Commissioning
        • Trainings
        • Maintenance
      • Company
        • Company
        • About Us
        • Company details
        • Certificates
        • News
        • Articles
      • Dealers
      • Support
      • Contacts
      • EN
        • Website
        • EN
        • RU
      • info@radmetron.com

      Illicit Trafficking of Nuclear and Radioactive Materials

      Radmetron | Main
      —
      Industries
      —
      Homeland Security
      —Illicit Trafficking of Nuclear and Radioactive Materials
      Transport RPMs
      9 products
      Pedestrian & Luggage RPMs
      4 products
      Radionuclide Identification Devices
      2 products
      Smart Probes
      5 products
      Contamination Measurement Radiometers
      2 products
      Contraband Detector
      1 product
      Radiation Monitoring System
      2 products
      Gamma PRDs
      2 products
      Gamma-Neutron PRDs
      1 product
      Filter
      By popularity (descending)
      By name (A-Z)
      By name (Z-A)
      By popularity (ascending)
      By popularity (descending)
      Coming soon
      Система радиационного контроля с информационным табло ИТ-РМ520М
      Radiation Monitoring System
      Radiation monitoring system with information display РМ520М
      Pending
      PM520M is designed to monitor the radiation situation and ensure the radiation safety at various facilities.

      PM520M has 3 versions:
      • PM520M-01 displays the measured DER value, current time and temperature;
      • PM520M-02 displays the measured DER value and current time;
      • PM520M-03 displays only the measured DER value.
      Detector — Geiger-Muller counter
      Measuring range of specific activity —
      0.1 µSv/h – 0.1 Sv/h (BDG2-1);
      0.1 µSv/h – 10.0 Sv/h (BDG2-2)

      Ambient dose equivalent rate (ADER) —
      50.0 keV – 3.0 MeV (BDG2-1);
      30.0 keV – 3.0 MeV (BDG2-2)

      Activity measurement sample density range — from −20 °С to 50 °С
      Alarm Type —
      built-in sound and light on PU
      light on ID
      additional external

      Dimensions —
      ID: 1050/750/400х70х135
      PU: 190х55х80
      DU: 165хØ40

      Ingress protection —
      DU: IP67
      PU: IP41
      ID: IP41 (IP67 on request)

      Supply voltage —
      12-24 V DC network;
      220 V AC network, 50 Hz (with adapter)

      Order
      Ask a Question
      Popular
      Recommended
      Дозиметр-радиометр поисковый МКС-РМ1401К-3
      Radionuclide Identification Devices/Contamination Measurement Radiometers
      Multipurpose Hand-Held Radiation Monitor/Identifier PM1401K-3
      On order

      PM1401K-3 is the smallest and the most lightweight instrument in the world, which is capable to operate simultaneously as an alarming device, search instrument, survey meter, spectrometer and identifier.

      The instrument can be used both indoors and outdoors and is intended for everyday and/or emergency use by officers of radiological and isotope laboratories, specialists of different industries, agriculture, transport, medicine, customs and border services, firefighters, military, police and other first responding agencies.


      Detector — Geiger-Mueller tube, CsI(Tl), He-3
      Type of registered radiation — α, β, photon, neutron
      Energy range of β-radiation flux density measurement — 150 keV - 3,5 MeV
      Energy range of the measures of neutron radiation — 0.025 eV - 14 MeV
      Energy range of the measures of photon radiation — 15 keV - 15 MeV
      Integral nonlinearity (INL) of spectrometer converstion characteristic — 1 %
      Energy resolution when acquairing scintillation spectra by 0.662 MeV (<sup>137</sup>Cs) line, no more — 9 %
      Quantity of accumulation channels — 1024
      Number of γ-radiation scintillation spectra saved in the instrument’s memory — at least 1000
      Ambient dose equivalent rate (ADER) of photon radiation measurement range — 0.1 μSv/h - 100 mSv/h
      α-radiation flux density measurement range — 15 - 105  min-1⋅cm-2
      β-radiation flux density measurement range — 6 - 105  min-1⋅cm-2
      <sup>137</sup>Cs activity concentrations measurement range — 102 - 105 Bq/kg (Bq/l)
      Ambient dose equivalent rate (ADER) of photon radiation indication range — 0.01 μSv/h - 200 mSv/h
      Accuracy of photon radiation ADER measurement — ±(15+0.0015/H) %; where H - measured ADER in mSv/h
      α-radiation flux density accuracy — ±(20 + 450/φα) %
      where φα - measured α-radiation flux density, min-1⋅cm-2
      β-radiation flux density accuracy — ±(20 + 60/φβ) %
      where φβ - measured β-radiation flux density, min-1⋅cm-2
      Accuracy of <sup>137</sup>Cs activity concentrations measurement — ±(30 + 2000/A) %
      where А - measured activity concentrations, Bq/kg (Bq/l)
      Energy response relative to 0.662 MeV (<sup>137</sup>Cs) — ±40 % for energy range 15 keV - 45 keV
      ±30 % for energy range 45 keV - 15 MeV
      Minimum detectable amounts of radioactive materials — gamma radiation sources
      at a distance of 0.2 m when moving at a speed of 0.5 m/s
      133Ba - 55 kBq
      137Cs - 100 kBq
        60Co - 50 kBq
      standard sample of plutonium - 0,3 г
      standard sample of uranium - 10 г

      neutron radiation sources
      at a distance of 1 m when moving at a speed of 0.5 m/s
      252Cf - 15 000 n/s
      standard sample of plutonium - 250 г
      Activity measurement sample density range — 0,2 - 1,6 g/cm3
      Alarm Type — Color LCD, audible, vibration (external)
      Radionuclide identification — yes
      PC communication — USB
      Positioning system — GPS
      Dimensions — 262 x 60 x 65 mm
      Weight — no more than 0,82 kg
      Ingress protection — IP65
      Drop test on concrete floor — 0.7 m
      Maximum permissible gamma radiation influence within 5 min — 1 Sv/h
      Mean recovery time — 1 h
      Mean service lifetime — 10 years
      Mean time between failyres, no less than — 20 000 h
      Atmospheric pressure — from 84.0 to 106.7 kPa
      Operating temperature — -30 °С up to 50 °С
      Humidity — up to 95 % at 35 °С
      Power source — 2 AA batteries
      Battery operating time, at least — 300 h on condition:
      ADER up to 0,3 μSv/h,
      backlight usage  up to 5 min/day,
      alarm duration up to 5 min/day
      Standards compliance — ANSI N42.33-2006, ANSI N42.34-2006,
      ANSI N42.42-2012, ANSI N42.48-2008,
      IEC 62327:2006
      Order
      Ask a Question
      Блок отображения информации БОИ PM-1403
      Smart Probes/Radionuclide Identification Devices
      Display and Control Unit PM1403

      Display and control unit is designed to display information when operates together with the external smart probes, to program its operation modes and to identify radionuclide composition. Display and control unit cannot be used independently. 

      The instrument indicates the menu and measurement results, stores the accumulated scintillation spectra in its permanent memory, enables communication with PC as well as receives GPS information and transfers data via USB and Bluetooth interfaces.


      Detector — no
      Operation mode setup time, no more — 60 s
      Dimensions — 155 х 85 х 38 mm
      Weight — 0.45 kg
      Ingress protection — IP65
      Mean recovery time — 60 min
      Mean service lifetime — 10 years
      Atmospheric pressure — from 84 to 106.7kPa
      Operating temperature — from -20 to +50 °С
      Humidity — up to 95 % at 35 °С
      Order
      Ask a Question
      Система радиационного контроля СРК-PM520
      Radiation Monitoring System
      Radiation Monitoring System PM520
      On order

      Radiation Monitoring System PM520 is designed for continuous gamma and neutron radiation monitoring of different facilities where radioactive sources are stored or processed.

      PM520 can be deployed in several separate locations or in passageways outdoors. Apart from other systems, PM520 has flexible configuration and uses up to 8 wall-mounted Gamma and Neutron Probes of different sensitivities and measurement ranges, main processing unit and remote PC for operation monitoring control with maximum distance between probes and unit up 1000 m. This configuration allows extending the range of controlled area with possibility of transferring measurement data to the single coordination center.

      Radiation Monitoring System can be used in different areas: nuclear facilities, waste management, areas and buildings with limited access, border/airport check points, places of storage and use of nuclear materials.


      Detector — Up to 8 detectors BDG2-Geiger-Muller; BDG3-CsI(Tl); BDN-slow neutron detector 3He
      Alarm Type — LED, Sound
      PC communication — RS-485 (up to 1000m), USB
      Configuration — Wall Mounted
      Ingress protection — IP65
      Atmospheric pressure — from 84 to 106.7
      Operating temperature — - 20 to 50 °С
      Humidity — up to 95%
      Order
      Ask a Question
      Coming soon
      Дозиметр-радиометр МКС-РМ1405Р
      Contamination Measurement Radiometers
      Survey meter PM1405P
      Pending
      Survey Meter PM1405P is used for monitoring the radiation situation, defining contaminated areas, measuring surface contamination of various objects.
      Detector — Geiger-Mueller tube
      Type of registered radiation — α, β, photon
      Energy range of the measures of photon radiation — 50 keV - 3 MeV
      Ambient dose equivalent rate (ADER) of photon radiation measurement range — 0.1 μSv/h - 300 mSv/h
      Ambient dose equivalent (ADE) of photon radiation measurement range — 0.1 μSv - 1.0 Sv
      α-radiation flux density measurement range — 2.0 - 105 min-1⋅cm-2
      β-radiation flux density measurement range — 6.0 - 105 min-1⋅cm-2
      Accuracy of photon radiation ADER measurement — ±20 %
      Accuracy of photon radiation ADE measurement — ±20 %
      α-radiation flux density accuracy — ±(20+450/φ) %
      where φ - measured α-radiation flux density, min-1⋅cm-2
      β-radiation flux density accuracy — ±(20+60/φ) %
      where φ - measured β-radiation flux density, min-1⋅cm-2
      Energy response relative to 0.662 MeV (<sup>137</sup>Cs) — ±30 %
      Data recording — at least 1000 events
      Alarm Type — visual, audible
      PC communication — USB type C
      Dimensions — 136 x 69 x 38 mm
      Weight — up to 340 g
      Ingress protection — IP65
      Atmospheric pressure — from 84.0 to 106.7 kPa
      Operating temperature — -20 °С up to 50 °С
      Humidity — up to 98 % at 40 °С
      Power source — rechargable or non-rechargable AA battery
      Battery operating time, at least — 3 month
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000B-10
      Transport RPMs
      Radiation Monitor PM5000B-10
      On order

      Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.

      Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.


      Type of registered radiation — gamma, neutron
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 4.5 m —
        8 km/h 20 km/h
      241Am, MBq, (µCi) 1.5 (41) 2.3 (62)
      137Cs, MBq, (µCi) 0.16 (4.3) 0.24 (6.5)
      60Co, MBq, (µCi) 0.10 (2.7) 0.15 (4.1)
       57Co, MBq, (µCi) 0.20 (5.4) 0.30 (8.1)
      133Ba, MBq, (µCi) 0.10 (2.7) 0.15 (4.1)
      238U, g 1300 1900
      235U, g 80 120
      239Pu,g 2.3 3.4
      239Pu, g (4 cm Pb)
      240
      400
      252Cf, neutron/s
      14000
      24000
      Number of detection units — 8 detectors
      Weight — one gamma detector – 120 kg; one neutron detector - 130 kg; control unit - 20 kg
      Ingress protection — IP65
      Mean recovery time — no more then 60 min
      Mean service lifetime — no less then 8 years
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — -30 up to +50°C
      Humidity — up to 98 % at 40°C and lower, no moisture
      Power source —
      industrial AC network (115-230V range) 47/63 Hz frequency
      built-in accumulator battery 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours).
      Power consumption —
      no more then 120 V•А.
      Order
      Ask a Question
      Блок детектирования нейтронного излучения БДН-PM1403
      Smart Probes
      Neutron Radiation Detector BDN for PM1403

      Neutron radiation detector BDN performs the following functions: measurement of DER of neutron radiation in collimated radiation by Pu-α-Be, search and registration of neutron radiation sources. 

      BDN can be used by radiological and isotope tracing laboratories, customs officers, emergency services to search and detect neutron radiation sources and to continuously monitor radiation environment.


      Detector — He-3
      Energy range — from thermal neutrons to 14 MeV
      Dose equivalent rate (DER) measurement range — from 1.0 to 5000 μSv/h (by Pu-α-Be source in collimated radiation)
      Count rate indication range in the search mode — from 1 to 4000 cps
      DER measurement accuracy — ± (30+K/Ḣ)%, where Ḣ – DER value, μSv/h; К – coefficient = 10.0 μSv/h
      Thresholds — from 1.0 to 5000 μSv/h
      Instrument sensitivity —
      for Pu-α-Be   0.65 impulses·cm2
      for thermal neutrons   4.5 impulses·cm2
      Alarm Type — visual, audible
      Data transfer — USB or RS-485 interface
      Dimensions — 230 x 63 mm
      Weight — 0.7 kg
      Ingress protection — IP65
      Drop test on concrete floor — 0.7 m
      Mean recovery time — 60 min
      Mean service lifetime — 10 years
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — from -20 to +50 °С
      Humidity — up to 95 % at 35 °С
      Supply voltage — 3.7 V (- 0.1; + 0.5) V
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000P-03B
      Pedestrian & Luggage RPMs
      Radiation monitor PM5000P-03B
      On order

      Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.

      Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.


      Type of registered radiation — gamma-neutron
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1 x 2 m —
      241Am, MBq, (µCi) 0.2 (5.5)
      137Cs, MBq, (µCi) 0.032 (0.87)
      60Co, MBq, (µCi) 0.018 (0.47)
      133Ba MBq, (µCi) 0.02 (0.55)
      238U, g 250
      235U, g 13.4
      239Pu, g 0.4
      239Pu, g (4 cm Pb) 42
      252Cf, neutron/s 2500
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 2 m —
      241Am, MBq, (µCi) 0.32 (8.7)
      137Cs, MBq, (µCi) 0.048 (1.3)
      60Co, MBq, (µCi) 0.026 (0.71)
      133Ba MBq, (µCi) 0.03 (0.8)
      238U, g 380
      235U, g 20
      239Pu, g 0.6
      239Pu, g (4 cm Pb) 62
      252Cf, neutron/s 3700
      Number of detection units — 2
      Alarm Type — light, audio
      PC communication — Ethernet port by means of a cable up to 100 m in length
      Maximum speed, km/h — 5
      Weight — 265 kg
      Mean recovery time — no more than 60 min
      Mean service lifetime — no less than 8 years
      Atmospheric pressure — from 84 to 106,7 kPa
      Operating temperature — -30... + 50 °C
      Humidity — up to 98% at 40 °C and colder, no moisture
      Power source —
      industrial AC network (from 85 to 264 V range) with from 47 to 63 Hz frequency
      built-in accumulator battery 12 V DC (back-up)
      Power consumption — no more than    60 VА
      Battery Lifetime —
      Accumulator battery continuous working of the monitor during 8 hours
      Order
      Ask a Question
      New
      Установка радиационного контроля УРК-РМ5000КМ-02
      Transport RPMs
      Radiation monitor PM5000KM-02
      On order

      Radiation Portal Monitors PM5000KM series are highly sensitive fixed-installation systems designed to control transport and luggage at stationary checkpoints for preventing illicit trafficking of radioactive materials.

      Energy range of the measures of photon radiation — 60 keV - 3 MeV
      Ambient dose equivalent rate (ADER) of photon radiation measurement range — 0.1 - 30 μSv/h (for energy 662 keV)
      Accuracy of photon radiation ADER measurement — ±30 %
      False alarm rate — 1/1000
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 5 km/h
      133Ba - 40 kBq
      137Cs - 50 kBq
       60Co - 24 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 15 km/h
      133Ba - 165 kBq
      137Cs - 200 kBq
       60Co - 95 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3.5 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,25 μSv/h
      when source is shielded with 1 mm of steel
      at source speed 10 km/h
      133Ba - 340 kBq
      137Cs - 410 kBq
       60Co - 210 kBq
      in long-dwell scan mode
      133Ba - 60 kBq
      137Cs - 70 kBq
       60Co - 35 kBq
      Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 3 m — with 0.5 probability and at least 0.95 confidence probability
      at gamma radiation background 0,1 μSv/h
      at source speed 15 km/h
      133Ba - 315 kBq
      137Cs - 390 kBq
       60Co - 190 kBq
      in long-dwell scan mode
      133Ba - 53 kBq
      137Cs - 67 kBq
       60Co - 32 kBq
      Number of detection units — 2
      PC communication — Ethernet, WiFi
      Ingress protection — IP65
      Mean recovery time — no more then 60 min
      Mean service lifetime — 15 years
      Mean time between failyres, no less than — 20 000 h
      Atmospheric pressure — from 84 to 106.7 kPa
      Operating temperature — -30 up to +50 °C
      -50 up to +50 °C with heating module
      Humidity — 98 %  at +40 °С and lower temperature
      Power source — AC mains, built-in accumulator
      Supply voltage — 90 - 132 V or 180 - 264 V, 47 - 63 Hz
      Power consumption — no more then 80 V⋅A (without video surveillance and heating)
      no more then 940 V⋅A (with video surveillance and heating)
      Battery Lifetime — 3 h
      Order
      Ask a Question
      Блок детектирования гамма-излучения БДГ3-PM1403
      Smart Probes
      Gamma Radiation Detector BDG3 for PM1403

      Gamma radiation detector BDG3 performs the following functions: measurement of dose equivalent rate (DER) of X-ray and gamma radiation, search for the photon radiation sources, registration and accumulation of photon radiation scintillation spectra.

      BDG3 can be used by emergency services, radiological and isotope laboratories, customs and border services, nuclear industry facilities, to search, detect and localize radioactive and nuclear sources and prevent illicit trafficking of radioactive and nuclear materials.


      Detector — Csl(TI)
      Energy range — 50 KeV – 3 MeV
      Quantity of accumulation channels —
      gamma-radiation scintillation spectra 1024
      Dose equivalent rate (DER) measurement range — from 0.1 to 40 μSv/h
      Count rate indication range in the search mode — from 1.0 to 9999 cps
      DER measurement accuracy — no more than ± 25 %
      Thresholds — from 0.1 to 40 μSv/h (DER levels)
      Instrument sensitivity —
      for 137Cs in the search mode 200.0 s-1/(μSv/h)
      Alarm Type — audible, visual
      Data transfer — RS-485 interface, USB
      Dimensions — 133 x 40 mm
      Weight — 0.2 kg
      Ingress protection — IP65
      Mean recovery time — 60 minutes
      Mean service lifetime — 10 years
      Atmospheric pressure — from 84 up to 106,7 kPa
      Operating temperature — from -20 up to + 50 °С
      Humidity — up to 95 % at 35 °С
      Supply voltage — 3.7 V ( - 0.1; + 0.5) V
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000P
      Pedestrian & Luggage RPMs
      Radiation monitor PM5000P
      On order

      Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.

      Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.

      Type of registered radiation — gamma
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1 x 2 m —
      241Am, MBq, (µCi) 0.4 (11)
      137Cs, MBq, (µCi) 0.08 (2)
      60Co, MBq, (µCi) 0.04 (1.1)
      133Ba MBq, (µCi) 0.05 (1.25)
      238U, g 470
      235U, g 30
      239Pu, g 0.8
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 2 m —
      241Am, MBq, (µCi) 0.7 (19)
      137Cs, MBq, (µCi) 0.13 (3.5)
      60Co, MBq, (µCi) 0.07 (1.9)
      133Ba MBq, (µCi) 0.08 (2.16)
      238U, g 815
      235U, g 50
      239Pu, g 1.4
      Number of detection units — 1
      Alarm Type — light, audio
      PC communication — Ethernet port by means of a cable up to 100 m in length
      Maximum speed, km/h — 5
      Weight — 125 kg
      Ingress protection — IP65
      Mean recovery time — no more than 60 min
      Mean service lifetime — no less than 8 years
      Atmospheric pressure — from 84 to 106,7 kPa
      Operating temperature — -30... + 50 °C
      Humidity — up to 98% at 40 °C and colder, no moisture
      Power source —
      industrial AC network (from 85 to 264 V range) with from 47 to 63 Hz frequency
      built-in accumulator battery 12 V DC (back-up)
      Power consumption —
      no more than 60 VА
      Battery Lifetime —
      Accumulator battery continuous working of the monitor during 8 hours
      Order
      Ask a Question
      Установка радиационного контроля УРК-PM5000P-01
      Pedestrian & Luggage RPMs
      Radiation monitor PM5000P-01
      On order

      Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.

      Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.

      Type of registered radiation — gamma
      Energy range — 20 KeV – 3 MeV
      Minimum detectable amounts of radioactive materials, control zone (L x H) 1 x 2 m —
      241Am, MBq, (µCi) 0.12 (3.2)
      137Cs, MBq, (µCi) 0.022 (0.59)
      60Co, MBq, (µCi) 0.012 (0.32)
      133Ba MBq, (µCi) 0.013 (0.36)
      238U, g 140
      235U, g 8.5
      239Pu, g 0.24

      Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 2 m —
      241Am, MBq, (µCi) 0.175 (4.75)
      137Cs, MBq, (µCi) 0.033 (0.88)
      60Co, MBq, (µCi) 0.0175 (0.475)
      133Ba MBq, (µCi) 0.02 (0.54)
      238U, g 205
      235U, g 12.5
      239Pu, g 0.36
      Number of detection units — 2
      Alarm Type — light, audio
      PC communication — Ethernet port by means of a cable up to 100 m in length
      Maximum speed, km/h — 5
      Weight — 245 kg
      Ingress protection — IP65
      Mean recovery time — no more than 60 min
      Mean service lifetime — no less than 8 years
      Atmospheric pressure — from 84 to 106,7 kPa
      Operating temperature — -30... + 50 °C
      Humidity — up to 98% at 40 °C and colder, no moisture
      Power source —
      industrial AC network (from 85 to 264 V range) with from 47 to 63 Hz frequency
      built-in accumulator battery 12 V DC (back-up)
      Power consumption —
      no more than 60 VА
      Battery Lifetime —
      Accumulator battery continuous working of the monitor during 8 hours
      Order
      Ask a Question
      Show more
      1 2 3
      • Nuclear Power
        • Personnel Exposure
        • Access Control
        • Workplace Safety
        • Calibration and Verification Equipment
      • Medical
        • Personnel Exposure
        • Radiation Area Monitoring
        • Waste control
      • Homeland Security
        • Radiation Security of Public Events & Sites
        • Emergency Response
        • Illicit Trafficking of Nuclear and Radioactive Materials
      • Oil & Gas | Mining
        • Exploration Geology
        • Soil Inspection
        • Inspection of Raw Materials, Waste & Goods
        • Surface Contamination
        • Radiation Safety in NDT
      • Industrial Safety
        • Personnel Exposure
        • Internal Control of IR sources
        • Inspection of Raw Materials, Waste & Goods
        • Laboratory Equipment
      Catalog
      Company
      Contacts
      Company details
      +375 (17) 336 68 68
      +375 (17) 336 68 68 Phone
      +375 (44) 773 44 44 Phone
      E-mail
      info@radmetron.com
      info@radmetron.com
      © 2025 Radmetron Ltd.
      All rigts reserved 
      ISO 9001 Certified
      ISO 9001 Certified
      Website Terms of Use and Personal Data Processing Policy
      A Cookie Policy
      Withdrawal of consent to the processing of personal data