Установка радиационного контроля УРК-РМ5000КМ-01
New
Radiation Portal Monitors PM5000KM series are highly sensitive fixed-installation systems designed to control transport, pedestrians, and luggage at stationary checkpoints for preventing illicit trafficking of radioactive materials.
Details
Characteristics
Energy range of the measures of photon radiation
—
60 keV - 3 MeV
Ambient dose equivalent rate (ADER) of photon radiation measurement range
—
0.1 - 30 μSv/h (for energy 662 keV)
Accuracy of photon radiation ADER measurement
—
±30 %
False alarm rate
—
1/1000
Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 3 m
—
with 0.5 probability and at least 0.95 confidence probability
at gamma radiation background 0,1 μSv/h
at source speed 5 km/h
133Ba - 135 kBq
137Cs - 150 kBq
60Co - 78 kBq
at gamma radiation background 0,1 μSv/h
at source speed 5 km/h
133Ba - 135 kBq
137Cs - 150 kBq
60Co - 78 kBq
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3 m
—
with 0.5 probability and at least 0.95 confidence probability
at gamma radiation background 0,1 μSv/h
at source speed 15 km/h
133Ba - 610 kBq
137Cs - 670 kBq
60Co - 350 kBq
at gamma radiation background 0,1 μSv/h
at source speed 15 km/h
133Ba - 610 kBq
137Cs - 670 kBq
60Co - 350 kBq
Установка радиационного контроля УРК-РМ5000КМ-01
Operation modes
Detection mode
Long-dwell scan mode
Dose equivalent rate measurement mode
Features
High sensitivity
Ease of installation
Audible and light alarms and an optional remote annunciator
Video surveillance (optional)
PC connection via Ethernet of WiFi
24/7 operation with the history recording
Suitable for use in harsh environment
Application
Border and customs checkpoints
Airports, seaports and railway stations
Nuclear waste disposal and storage sites
NPPs and nuclear industry enterprises
Petrochemical and metallurgical industry
Medical and research institutions
Governmental buildings, banks, postal terminals
Scrap metal industry
Characteristics
Energy range of the measures of photon radiation
|
60 keV - 3 MeV |
Ambient dose equivalent rate (ADER) of photon radiation measurement range
|
0.1 - 30 μSv/h (for energy 662 keV) |
Accuracy of photon radiation ADER measurement
|
±30 % |
False alarm rate
|
1/1000 |
Minimum detectable amounts of radioactive materials, control zone (L x H) 1.5 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability at gamma radiation background 0,1 μSv/h at source speed 5 km/h 133Ba - 135 kBq 137Cs - 150 kBq 60Co - 78 kBq |
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability at gamma radiation background 0,1 μSv/h at source speed 15 km/h 133Ba - 610 kBq 137Cs - 670 kBq 60Co - 350 kBq |
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 3.5 m
|
with 0.5 probability and at least 0.95 confidence probability at gamma radiation background 0,25 μSv/h when source is shielded with 1 mm of steel at source speed 10 km/h 133Ba - 1060 kBq 137Cs - 1170 kBq 60Co - 610 kBq in long-dwell scan mode 133Ba - 185 kBq 137Cs - 205 kBq 60Co - 105 kBq |
Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 3 m
|
with 0.5 probability and at least 0.95 confidence probability at gamma radiation background 0,1 μSv/h at source speed 15 km/h 133Ba - 1350 kBq 137Cs - 1470 kBq 60Co - 760 kBq in long-dwell scan mode 133Ba - 230 kBq 137Cs - 250 kBq 60Co - 135 kBq |
Number of detection units
|
1 |
PC communication
|
Ethernet, WiFi |
Ingress protection
|
IP65 |
Mean recovery time
|
no more then 60 min |
Mean service lifetime
|
15 years |
Mean time between failyres, no less than
|
20 000 h |
Atmospheric pressure
|
from 84 to 106.7 kPa |
Operating temperature
|
-30 up to +50 °C -50 up to +50 °C with heating module |
Humidity
|
98 % at +40 °С and lower temperature |
Power source
|
AC mains, built-in accumulator |
Supply voltage
|
90 - 132 V or 180 - 264 V, 47 - 63 Hz |
Power consumption
|
no more then 60 V⋅A (without video surveillance and heating) no more then 520 V⋅A (with video surveillance and heating) |
Battery Lifetime
|
6 h |