Radiation monitoring system with information display РМ520М
Coming soon
PM520M is designed to monitor the radiation situation and ensure the radiation safety at various facilities.
PM520M has 3 versions:
Details
PM520M has 3 versions:
- PM520M-01 displays the measured DER value, current time and temperature;
- PM520M-02 displays the measured DER value and current time;
- PM520M-03 displays only the measured DER value.
Characteristics
Detector
—
Geiger-Muller counter
Measuring range of specific activity
—
0.1 µSv/h – 0.1 Sv/h (BDG2-1);
0.1 µSv/h – 10.0 Sv/h (BDG2-2)
0.1 µSv/h – 10.0 Sv/h (BDG2-2)
Ambient dose equivalent rate (ADER)
—
50.0 keV – 3.0 MeV (BDG2-1);
30.0 keV – 3.0 MeV (BDG2-2)
30.0 keV – 3.0 MeV (BDG2-2)
Activity measurement sample density range
—
from −20 °С to 50 °С
Alarm Type
—
built-in sound and light on PU
light on ID
additional external
light on ID
additional external
Dimensions
—
ID: 1050/750/400х70х135
PU: 190х55х80
DU: 165хØ40
PU: 190х55х80
DU: 165хØ40
Radiation monitoring system with information display РМ520М
PM520M includes an Information Display (ID), a Processing Unit (PU) and a Gamma Radiation Detection Unit (DU).
ID and DU are connected to the PU and powered via the RS485 communication line up to 1000 m.
PU is powered from a 12-24 V DC power supply. The PM520M includes a 220 V/12 V AC power adapter (optional).
DU continuously measures the ambient dose equivalent rate (DER) and displays the measurement result on the ID. The software allows you to set the DER threshold value. When threshold value is exceeded, sound and light alarms are triggered. The PM520M includes an external additional sound and light signaling device (optional).
PU has a built-in non-volatile memory for storing information about the instrument operation. PU can be connected to a PC via the USB interface for configuration, diagnostics and viewing information stored in the non-volatile memory.
PM520M has 3 versions:
ID and DU are connected to the PU and powered via the RS485 communication line up to 1000 m.
PU is powered from a 12-24 V DC power supply. The PM520M includes a 220 V/12 V AC power adapter (optional).
DU continuously measures the ambient dose equivalent rate (DER) and displays the measurement result on the ID. The software allows you to set the DER threshold value. When threshold value is exceeded, sound and light alarms are triggered. The PM520M includes an external additional sound and light signaling device (optional).
PU has a built-in non-volatile memory for storing information about the instrument operation. PU can be connected to a PC via the USB interface for configuration, diagnostics and viewing information stored in the non-volatile memory.
PM520M has 3 versions:
- PM520M-01 displays the measured DER value, current time and temperature;
- PM520M-02 displays the measured DER value and current time;
- PM520M-03 displays only the measured DER value.
Characteristics
Detector
|
Geiger-Muller counter |
Measuring range of specific activity
|
0.1 µSv/h – 0.1 Sv/h (BDG2-1);
0.1 µSv/h – 10.0 Sv/h (BDG2-2) |
Ambient dose equivalent rate (ADER)
|
50.0 keV – 3.0 MeV (BDG2-1);
30.0 keV – 3.0 MeV (BDG2-2) |
Activity measurement sample density range
|
from −20 °С to 50 °С |
Alarm Type
|
built-in sound and light on PU
light on ID additional external |
Dimensions
|
ID: 1050/750/400х70х135
PU: 190х55х80 DU: 165хØ40 |
Ingress protection
|
DU: IP67
PU: IP41 ID: IP41 (IP67 on request) |
Supply voltage
|
12-24 V DC network;
220 V AC network, 50 Hz (with adapter) |
Advertising: