scintillator with SiPM
Functions
Measurement of personal dose equivalent and personal dose equivalent rate of continuous and pulsed photon radiation
Measurement of personal dose equivalent and personal dose equivalent rate of neutron radiation
Alarming in case preset dose or dose rate thresholds exceed
Recording up to 10 000 events in the history
Wireless data exchange via RF-interface and wired data exchange via USB-interface
Advantages
Range of registered energies of photon radiation from 15 keV to 20 MeV
Range of registered energies of neutron radiation from 0.25 eV to 15 MeV
Battery operating time up to 45 days
Quick response to the dose rate changes
Possibility of remote, real-time control of personnel dose exposure
Application
Nuclear power plants and fuel cycle facilities
Oil, gas and mining industry
Medical institutions
Radiological and isotope laboratories
Processing and transportation of radioactive materials
RF interface
Dosimeter is equipped with a wireless data exchange module which allows automated registration of the personnel in exposure monitoring system and issuing personal radiological work permits; simultaneous transmission of measurement results to the personnel exposure monitoring system from several dosimeters; remote control of the access, movement, location and duty hours of personnel in the restricted areas under issued radiological work permits; integration to automatic access control systems.
The reader may be located autonomously in different zones of the controlled areas and simultaneously receive data from several dosimeters in the acquisition range and also may be built in different gadgets like turn gates, info desks, etc.
Standards Compliance
Complies and exceeds the requirements of IEC 61526, ANSI 42.20
Detector
|
energy compensated silicon PIN diode, scintillator with SiPM |
Energy range of the measures of neutron radiation
|
0.025 eV - 15 MeV |
Energy range of the measures of photon radiation
|
15 keV - 20 MeV |
Personal dose equivalent rate (PDER) of neutron radiation measurement range
|
50 μSv/h - 200 mSv/h |
Personal dose equivalent rate (PDER) of continuous photon radiation measurement range
|
1,0 μSv/h - 10 Sv/h |
Average personal dose equivalent rate (PDER) of pulsed photon radiation measurement range
|
10 mSv/h - 10 Sv/h |
Personal dose equivalent (PDE) of neutron radiation measurement range
|
10 μSv - 20 Sv |
Personal dose equivalent (PDE) of photon radiation measurement range
|
1,0 μSv - 20 Sv |
Personal dose equivalent rate (PDER) of neutron radiation indication range
|
0.01 μSv/h - 1 Sv/h |
Personal dose equivalent rate (PDER) of photon radiation indication range
|
0.01 μSv/h - 10 Sv/h |
Personal dose equivalent (PDE) of photon radiation indication range
|
0.01 μSv - 20 Sv |
Accuracy of neutron radiation PDER measurement
|
±(15+375/√(t⋅Hp(10)) %, where t - measurement time, h Hp(10) - PDER value, μSv/h |
Accuracy of continuous photon radiation PDER measurement
|
±15 % |
Accuracy of pulsed photon radiation avrage PDER measurement
|
±15 % |
Accuracy of neutron radiation PDE measurement
|
±(15+100/√Hp(10)) % where Hp(10) - PDE value, μSv |
Accuracy of photon radiation PDE measurement
|
±15 % |
Energy response relative to 0.662 MeV (137Cs)
|
±15 % for energy range 15 keV - 7 MeV ±40 % for energy range 7 MeV - 20 MeV |
Energy response relative to collimated neutron radiation from 239Pu-Be source
|
-30 to + 80 % |
Thresholds
|
2 for PDE and 2 for PDER |
Threshold setting range
|
for PDER of neutron radiation: 50 μSv/h - 200 mSv/h of photon radiation: 1 μSv/h - 10 Sv/h for PDE of neutron radiation: 10 μSv - 20 Sv of photon radiation: 1 μSv - 20 Sv |
Operation mode setup time, no more
|
20 s |
Data recording
|
10 000 events |
Alarm Type
|
audible, visual, vibration |
PC communication
|
USB, RF |
Dimensions
|
130 х 57 х 25 mm |
Weight
|
up to 200 g |
Radiation resistance, at least
|
100 Gy |
Ingress protection
|
IP67 |
Drop test on concrete floor
|
1.5 m |
Mean recovery time
|
1 h |
Mean service lifetime
|
10 years |
Mean time between failyres, no less than
|
20 000 h |
Atmospheric pressure
|
from 84 to 106.7 kPa |
Operating temperature
|
-20 °С up to 50 °С |
Humidity
|
up to 95 % at 40 °С |
Resistance to decontamination solutions
|
Solution № 1: NaOH 30 - 40 g/l, KMnO4 2 - 5 g/l Solution № 2: H2C2O4 10 - 30 g/l, HNO3 1 g/l |
Power source
|
AAA (LR03) battery or NiMH battery |
Battery operating time, at least
|
900 h on condition: - PDER up to 0.25 μSv/h - backlight usage up to 20 min/day - alarm duration up to 1 min/day |