Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
5 km/h | |
239Pu,g (4 cm Pb) | 110 |
252Cf, neutron/s | 6500 |
8 km/h | |
239Pu,g (4 cm Pb) |
340 |
252Cf, neutron/s |
20000 |
Operation Principle
RPMs have modular design and may have one-pillar or two-pillar configurations, adaptable height and width according to customer requirements. Monitors can be equipped with video monitoring system.
Key Features
- High sensitivity
- Advanced data processing algorithms
- Modular design
- Easy-in-use
- Audible and light alarms
- Indoor and outdoor installations
- Reliable, automatic, 24/7 operation
- PC connection through the Ethernet port
- Video monitoring system (option)
- Integration into a nuclear protection network controlled by a central PC (option) with further integration into higher level networks controlled by an Expert Center (option)
Modifications
- РМ5000В-01 - two-pillar gamma monitor with 4 gamma radiation detector modules;
- РМ5000В-05 - two-pillar gamma monitor with 2 gamma radiation detector modules;
- РМ5000В-09 - two-pillar gamma-neutron monitor with 2 gamma-neutron radiation detector modules on 10B / ZnS (Ag) basis;
- РМ5000В-10 - two-pillar gamma-neutron monitor with 4 gamma and 4 neutron radiation detector modules on 10B / ZnS (Ag) basis;
- РМ5000В-13 - two-pillar neutron monitor with 2 neutron detector modules on 10B / ZnS (Ag) basis;
- РМ5000В-14 - two-pillar neutron monitor with 4 neutron detector modules on 10B / ZnS (Ag) basis;
- РМ5000В-16 - two-pillar gamma monitor which consists of 8 gamma radiation detector modules;
Monitored objects:
- Cars
- Pedestrians
- Luggage
Type of registered radiation
|
neutron | ||||||
Energy range
|
20 KeV – 3 MeV | ||||||
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 2 m
|
|
||||||
Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 2 m
|
|
||||||
Number of detection units
|
2 detectors | ||||||
Weight
|
one neutron detector - 130 kg; control unit - 20 kg | ||||||
Ingress protection
|
IP65 | ||||||
Mean recovery time
|
no more then 60 min | ||||||
Mean service lifetime
|
no less then 8 years | ||||||
Atmospheric pressure
|
from 84 to 106.7 kPa | ||||||
Operating temperature
|
-30 up to +50°C | ||||||
Humidity
|
up to 98 % at 40°C and lower, no moisture | ||||||
Power source
|
|
||||||
Power consumption
|
|