Radiation Monitor PM5000B-09
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
Characteristics
Type of registered radiation
—
gamma, neutron
Energy range
—
20 KeV – 3 MeV
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 2 m
—
5 km/h | |
241Am, MBq, (µCi) | 0.62 (17) |
137Cs, MBq, (µCi) | 0.065 (1.8) |
60Co, MBq (µCi) |
0.040 (1.1) |
57Co, MBq, (µCi) |
0.085 (2.3) |
133Ba, MBq (µCi) | 0.040 (1.1) |
238U, g | 460 |
235U, g | 32 |
239Pu,g | 0.9 |
239Pu,g (4 cm Pb) | 110 |
252Cf, neutron/s | 6500 |
Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 2 m
—
8 km/h | |
241Am, MBq, (µCi) |
2.15 (58) |
137Cs, MBq, (µCi) |
0.23 (6.2) |
60Co, MBq (µCi) |
0.145 (3.9) |
57Co, MBq, (µCi) | 0.29 (7.8) |
133Ba, MBq (µCi) |
0.145 (3.9) |
238U, g |
1800 |
235U, g |
110 |
239Pu,g |
3.2 |
239Pu,g (4 cm Pb) |
340 |
252Cf, neutron/s |
20000 |
Number of detection units
—
4 detectors
Weight
—
one gamma detector – 120 kg; one neutron detector - 130 kg; control unit - 20 kg
Radiation Monitor PM5000B-09
Operation Principle
RPMs have modular design and may have one-pillar or two-pillar configurations, adaptable height and width according to customer requirements. Monitors can be equipped with video monitoring system.
Key Features
- High sensitivity
- Advanced data processing algorithms
- Modular design
- Easy-in-use
- Audible and light alarms
- Indoor and outdoor installations
- Reliable, automatic, 24/7 operation
- PC connection through the Ethernet port
- Video monitoring system (option)
- Integration into a nuclear protection network controlled by a central PC (option) with further integration into higher level networks controlled by an Expert Center (option)
Modifications
- РМ5000В-01 - two-pillar gamma monitor with 4 gamma radiation detector modules;
- РМ5000В-05 - two-pillar gamma monitor with 2 gamma radiation detector modules;
- РМ5000В-09 - two-pillar gamma-neutron monitor with 2 gamma-neutron radiation detector modules on 10B / ZnS (Ag) basis;
- РМ5000В-10 - two-pillar gamma-neutron monitor with 4 gamma and 4 neutron radiation detector modules on 10B / ZnS (Ag) basis;
- РМ5000В-13 - two-pillar neutron monitor with 2 neutron detector modules on 10B / ZnS (Ag) basis;
- РМ5000В-14 - two-pillar neutron monitor with 4 neutron detector modules on 10B / ZnS (Ag) basis;
- РМ5000В-16 - two-pillar gamma monitor which consists of 8 gamma radiation detector modules;
Monitored objects:
- Cars
- Pedestrians
- Luggage
Characteristics
Type of registered radiation
|
gamma, neutron | ||||||||||||||||||||||
Energy range
|
20 KeV – 3 MeV | ||||||||||||||||||||||
Minimum detectable amounts of radioactive materials, control zone (L x H) 3 x 2 m
|
|
||||||||||||||||||||||
Minimum detectable amounts of radioactive materials, control zone (L x H) 6 x 2 m
|
|
||||||||||||||||||||||
Number of detection units
|
4 detectors | ||||||||||||||||||||||
Weight
|
one gamma detector – 120 kg; one neutron detector - 130 kg; control unit - 20 kg | ||||||||||||||||||||||
Ingress protection
|
IP65 | ||||||||||||||||||||||
Mean recovery time
|
no more then 60 min | ||||||||||||||||||||||
Mean service lifetime
|
no less then 8 years | ||||||||||||||||||||||
Atmospheric pressure
|
from 84 to 106.7 kPa | ||||||||||||||||||||||
Operating temperature
|
-30 up to +50°C | ||||||||||||||||||||||
Humidity
|
up to 100 % at 35°C and lower, no moisture | ||||||||||||||||||||||
Power source
|
|
||||||||||||||||||||||
Power consumption
|
|
Advertising: