Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.2 (5.5) |
137Cs, MBq, (µCi) | 0.032 (0.87) |
60Co, MBq, (µCi) | 0.018 (0.47) |
133Ba MBq, (µCi) | 0.02 (0.55) |
238U, g | 250 |
235U, g | 13.4 |
239Pu, g | 0.4 |
239Pu, g (4 cm Pb) | 42 |
252Cf, neutron/s | 2500 |
241Am, MBq, (µCi) | 0.32 (8.7) |
137Cs, MBq, (µCi) | 0.048 (1.3) |
60Co, MBq, (µCi) | 0.026 (0.71) |
133Ba MBq, (µCi) | 0.03 (0.8) |
238U, g | 380 |
235U, g | 20 |
239Pu, g | 0.6 |
239Pu, g (4 cm Pb) | 62 |
252Cf, neutron/s | 3700 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.4 (11) |
137Cs, MBq, (µCi) | 0.08 (2) |
60Co, MBq, (µCi) | 0.04 (1.1) |
133Ba MBq, (µCi) | 0.05 (1.25) |
238U, g | 470 |
235U, g | 30 |
239Pu, g | 0.8 |
241Am, MBq, (µCi) | 0.7 (19) |
137Cs, MBq, (µCi) | 0.13 (3.5) |
60Co, MBq, (µCi) | 0.07 (1.9) |
133Ba MBq, (µCi) | 0.08 (2.16) |
238U, g | 815 |
235U, g | 50 |
239Pu, g | 1.4 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.12 (3.2) |
137Cs, MBq, (µCi) | 0.022 (0.59) |
60Co, MBq, (µCi) | 0.012 (0.32) |
133Ba MBq, (µCi) | 0.013 (0.36) |
238U, g | 140 |
235U, g | 8.5 |
239Pu, g | 0.24 |
241Am, MBq, (µCi) | 0.175 (4.75) |
137Cs, MBq, (µCi) | 0.033 (0.88) |
60Co, MBq, (µCi) | 0.0175 (0.475) |
133Ba MBq, (µCi) | 0.02 (0.54) |
238U, g | 205 |
235U, g | 12.5 |
239Pu, g | 0.36 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.75 (20) |
137Cs, MBq, (µCi) | 0.12 (3.2) |
60Co, MBq, (µCi) | 0.65 (1.8) |
133Ba MBq, (µCi) | 0.075 (2) |
238U, g | 870 |
235U, g | 47 |
239Pu, g | 1.4 |
239Pu, g (4 cm Pb) | 110 |
252Cf, neutron/s | 6500 |
241Am, MBq, (µCi) | 1.29 (35) |
137Cs, MBq, (µCi) | 0.21 (5.6) |
60Co, MBq, (µCi) | 0.11 (3) |
133Ba MBq, (µCi) | 0.13 (3.5) |
238U, g | 1500 |
235U, g | 80 |
239Pu, g | 2.3 |
239Pu, g (4 cm Pb) | 190 |
252Cf, neutron/s | 11250 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |