Personal radiation detector PM1401MA is designed for detecting of gamma radiation sources. Due to its hermetic and shockproof case and the LCD screen fluorescent backlight, instrument can be used in extreme and harsh environments. For work in difficult-to-access areas telescopic extension tube is provided. PRD has audible, visual and vibrating alarms, records and stores up to 1000 events in non-volatile memory and transmits data to a PC via USB interface.
PM1401MA is recommended for first responders, security guards, police, customs officers and border patrol. No special experience or training is necessary to operate the instrument.
Detector
—
Csl(TI) scintillator
Energy range
—
50 keV – 3 MeV
Dose equivalent rate (DER) measurement range
—
0.05 µSv/h – 40 µSv/h / (5 µR/h – 4000 µR/h)
DER indication range
—
0.01 µSv/h – 99.99 µSv/h / (1 µR/h – 9999 µR/h)
DER measurement accuracy
—
±(20+1/Ḣ)%, where Ḣ = DER, μSv/h
Response time
—
0.25 s |
Data recording
—
990 data points
Alarm Type
—
visual, audible and external vibrator
PC communication
—
USB
Dimensions
—
110х62х38 mm (41/3 х 21/2 х 11/2 in)
Weight
—
320 g. (11.29 oz) - including battery
Ingress protection
—
IP65
Drop test on concrete floor
—
0.7 m (2.3 ft.) onto concrete surface
Operating temperature
—
-30°C to 50°C (-22°F to 122°F); LCD -15 to +50 °C (+5 to +122,5 °F )
Humidity
—
up to 95 % at +35 °C (+95 °F )
Battery Lifetime
—
at least 800 hours |
Order
Gamma-Neutron PRDs
On order
Gamma-neutron personal radiation detectors PM1401GNM are designed to detect the slightest amounts of gamma and neutron radioactive materials in harsh environmental conditions and difficult-to-access areas. Instruments are lightweight, have hermetic and shockproof case, non-volatile memory for data storage, small size and user-friendly interface.
Detector
—
CsI(Tl) scintillator, 3He, Geiger-Muller tube
Energy range of the measures of neutron radiation
—
0.025 eV – 14 MeV
Energy range of the measures of photon radiation
—
33 keV – 3 MeV
Dose equivalent rate (DER) measurement range
—
0.1 – 9999 μSv/h |
DER indication range
—
0.01 – 9999 μSv/h |
Neutron count rate indication range
—
1.0 - 99 с-1 |
DER measurement accuracy
—
±20% |
Sensitivity to neutron radiation
—
for Pu-α-Be | 0.1 (counts·cm2)/neutron |
for heat neutrons | 7.0 (counts·cm2)/neutron |
for Pu-a-Be, at use of chamber-moderator or on phantom | 1.0 (counts·cm2)/neutron |
Time-to-alarn; neutrons
—
2 s (corresponds to ANSI N42.32)
Time-to-alarm; photons
—
2 s (corresponds to ANSI N42.32)
Alarm Type
—
visual, audio, vibration (external)
PC communication
—
USB
Dimensions
—
195х57х32 mm
Weight
—
0.45 kg
Ingress protection
—
IP65
Drop test on concrete floor
—
0.7 m
Atmospheric pressure
—
from 84 to 106.7 kPa
Operating temperature
—
-30°C to 50°C; (LCD from -15°C to +50 °C)
Humidity
—
up to 98 % at 35 °C (+95 °F)
Supply voltage
—
1.5 (+ 0.1; - 0.4) V (one АА battery (LR6))
Battery Lifetime
—
no less 800 h
Order
Gamma PRDs
Pending
Detailed information will be provided soon. Please don`t hesitate to contact us if you have any question.