Spectroscopic Radiation Monitor PM1403 is designed for measurement of ADER of gamma radiation, searching for radioactive sources, registration and accumulation of scintillation spectra and radionuclide identification. External smart probes and built-in Csl(TI) detector make PM1403 a powerful tool for detection and localization of gamma, neutron, alpha and beta radiation sources. Instrument has built-in GPS/GLONASS, GSM/GPRS, Bluetooth® 2.0. modules for data exchange. Non-volatile memory enables saving accumulated scintillation spectra.
Instrument is recommended to first responders, customs and border patrol, police, emergency teams, law enforcement, hazmat teams, security guards.
133Ba - 55 kBq
137Cs - 100 kBq
60Co - 50 kBq
- without GPRS and WiFi usage
- without usage of external detectors
8 h on condition:
- without GPRS and WiFi usage
- with external detector
Radiation Monitoring System PM520 is designed for continuous gamma and neutron radiation monitoring of different facilities where radioactive sources are stored or processed.
PM520 can be deployed in several separate locations or in passageways outdoors. Apart from other systems, PM520 has flexible configuration and uses up to 8 wall-mounted Gamma and Neutron Probes of different sensitivities and measurement ranges, main processing unit and remote PC for operation monitoring control with maximum distance between probes and unit up 1000 m. This configuration allows extending the range of controlled area with possibility of transferring measurement data to the single coordination center.
Radiation Monitoring System can be used in different areas: nuclear facilities, waste management, areas and buildings with limited access, border/airport check points, places of storage and use of nuclear materials.
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.2 (5.5) |
137Cs, MBq, (µCi) | 0.032 (0.87) |
60Co, MBq, (µCi) | 0.018 (0.47) |
133Ba MBq, (µCi) | 0.02 (0.55) |
238U, g | 250 |
235U, g | 13.4 |
239Pu, g | 0.4 |
239Pu, g (4 cm Pb) | 42 |
252Cf, neutron/s | 2500 |
241Am, MBq, (µCi) | 0.32 (8.7) |
137Cs, MBq, (µCi) | 0.048 (1.3) |
60Co, MBq, (µCi) | 0.026 (0.71) |
133Ba MBq, (µCi) | 0.03 (0.8) |
238U, g | 380 |
235U, g | 20 |
239Pu, g | 0.6 |
239Pu, g (4 cm Pb) | 62 |
252Cf, neutron/s | 3700 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.75 (20) |
137Cs, MBq, (µCi) | 0.12 (3.2) |
60Co, MBq, (µCi) | 0.65 (1.8) |
133Ba MBq, (µCi) | 0.075 (2) |
238U, g | 870 |
235U, g | 47 |
239Pu, g | 1.4 |
239Pu, g (4 cm Pb) | 110 |
252Cf, neutron/s | 6500 |
241Am, MBq, (µCi) | 1.29 (35) |
137Cs, MBq, (µCi) | 0.21 (5.6) |
60Co, MBq, (µCi) | 0.11 (3) |
133Ba MBq, (µCi) | 0.13 (3.5) |
238U, g | 1500 |
235U, g | 80 |
239Pu, g | 2.3 |
239Pu, g (4 cm Pb) | 190 |
252Cf, neutron/s | 11250 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.12 (3.2) |
137Cs, MBq, (µCi) | 0.022 (0.59) |
60Co, MBq, (µCi) | 0.012 (0.32) |
133Ba MBq, (µCi) | 0.013 (0.36) |
238U, g | 140 |
235U, g | 8.5 |
239Pu, g | 0.24 |
241Am, MBq, (µCi) | 0.175 (4.75) |
137Cs, MBq, (µCi) | 0.033 (0.88) |
60Co, MBq, (µCi) | 0.0175 (0.475) |
133Ba MBq, (µCi) | 0.02 (0.54) |
238U, g | 205 |
235U, g | 12.5 |
239Pu, g | 0.36 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Monitors of PM5000P Series are designed to monitor gamma or neutron or both gamma and neutron radiation in vehicles and luggage at various checkpoints. Radiation monitors may have one-pillar or two-pillar configurations depending on the site requirements, and can be installed both indoor or outdoor.
Radiation Monitors can be installed at vehicular, railway and pedestrian border crossings, at customs checkpoints to prevent the illicit penetration of the radioactive sources into the country or the limited-access areas, checkpoints of Nuclear power plants (NPPs), nuclear industry facilities, nuclear waste disposal and storage sites, check points in banks, offices.
241Am, MBq, (µCi) | 0.4 (11) |
137Cs, MBq, (µCi) | 0.08 (2) |
60Co, MBq, (µCi) | 0.04 (1.1) |
133Ba MBq, (µCi) | 0.05 (1.25) |
238U, g | 470 |
235U, g | 30 |
239Pu, g | 0.8 |
241Am, MBq, (µCi) | 0.7 (19) |
137Cs, MBq, (µCi) | 0.13 (3.5) |
60Co, MBq, (µCi) | 0.07 (1.9) |
133Ba MBq, (µCi) | 0.08 (2.16) |
238U, g | 815 |
235U, g | 50 |
239Pu, g | 1.4 |
industrial AC network | (from 85 to 264 V range) with from 47 to 63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up) |
no more than | 60 VА |
Accumulator battery | continuous working of the monitor during 8 hours |
Radiation Portal Monitors PM5000KM series are highly sensitive fixed-installation systems designed to control transport, pedestrians, and luggage at stationary checkpoints for preventing illicit trafficking of radioactive materials.
at gamma radiation background 0,1 μSv/h
at source speed 5 km/h
133Ba - 40 kBq
137Cs - 50 kBq
60Co - 24 kBq
at gamma radiation background 0,1 μSv/h
at source speed 15 km/h
133Ba - 165 kBq
137Cs - 200 kBq
60Co - 95 kBq
at gamma radiation background 0,25 μSv/h
when source is shielded with 1 mm of steel
at source speed 10 km/h
133Ba - 340 kBq
137Cs - 410 kBq
60Co - 210 kBq
in long-dwell scan mode
133Ba - 60 kBq
137Cs - 70 kBq
60Co - 35 kBq
at gamma radiation background 0,1 μSv/h
at source speed 15 km/h
133Ba - 315 kBq
137Cs - 390 kBq
60Co - 190 kBq
in long-dwell scan mode
133Ba - 53 kBq
137Cs - 67 kBq
60Co - 32 kBq
-50 up to +50 °C with heating module
no more then 940 V⋅A (with video surveillance and heating)
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
8 km/h | 20 km/h | |
241Am, MBq, (µCi) |
1.15 (31) |
1.8 (49) |
137Cs, MBq, (µCi) | 0.16 (4.3) | 0.185 (5) |
60Co, MBq, (µCi) | 0.075 (2) | 0.115 (3.1) |
57Co, MBq, (µCi) |
0.155 (4.2) |
0.230 (6.2) |
133Ba, MBq, (µCi) | 0.10 (2.7) |
0.115 (3.1) |
238U, g |
1000 |
1500 |
235U, g | 62 | 92 |
239Pu, g | 1.9 | 2.8 |
industrial AC network (115-230V range) | 47/63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours). |
no more then | 120 V•А. |
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
239Pu, g (4 cm Pb); speed 5 km/h. | 75 |
252Cf, neutron/s; speed 5 km/h. | 4500 |
8 km/h | |
239Pu,g (4 cm Pb) |
340 |
252Cf, neutron/s |
20000 |
8 km/h | 20 km/h | |
239Pu,g (4 cm Pb) |
240 |
400 |
252Cf, neutron/s |
14000 |
24000 |
industrial AC network (115-230V range) | 47/63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours). |
no more then | 120 V•А. |
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
5 km/h | |
239Pu,g (4 cm Pb) | 110 |
252Cf, neutron/s | 6500 |
8 km/h | |
239Pu,g (4 cm Pb) |
340 |
252Cf, neutron/s |
20000 |
industrial AC network (115-230V range) | 47/63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours). |
no more then | 120 V•А. |
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
8 km/h | 20 km/h | |
241Am, MBq, (µCi) | 1.5 (41) | 2.3 (62) |
137Cs, MBq, (µCi) | 0.16 (4.3) | 0.24 (6.5) |
60Co, MBq, (µCi) | 0.10 (2.7) | 0.15 (4.1) |
57Co, MBq, (µCi) | 0.20 (5.4) | 0.30 (8.1) |
133Ba, MBq, (µCi) | 0.10 (2.7) | 0.15 (4.1) |
238U, g | 1300 | 1900 |
235U, g | 80 | 120 |
239Pu,g | 2.3 | 3.4 |
239Pu, g (4 cm Pb) |
240 |
400 |
252Cf, neutron/s |
14000 |
24000 |
industrial AC network (115-230V range) | 47/63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours). |
no more then | 120 V•А. |
Radiation Portal Monitors (RPMs) of PM5000B Series are highly sensitive fixed installation systems designed to automatically detect illicit trafficking of radioactive materials.
Application: airports, seaports, railway stations, customs and border checkpoints, nuclear plants and other facilities of the nuclear industry, nuclear waste disposal and storage sites, scrap metal industry, governmental offices, banks and post offices.
5 km/h | |
241Am, MBq, (µCi) | 0.62 (17) |
137Cs, MBq, (µCi) | 0.065 (1.8) |
60Co, MBq (µCi) |
0.040 (1.1) |
57Co, MBq, (µCi) |
0.085 (2.3) |
133Ba, MBq (µCi) | 0.040 (1.1) |
238U, g | 460 |
235U, g | 32 |
239Pu,g | 0.9 |
239Pu,g (4 cm Pb) | 110 |
252Cf, neutron/s | 6500 |
8 km/h | |
241Am, MBq, (µCi) |
2.15 (58) |
137Cs, MBq, (µCi) |
0.23 (6.2) |
60Co, MBq (µCi) |
0.145 (3.9) |
57Co, MBq, (µCi) | 0.29 (7.8) |
133Ba, MBq (µCi) |
0.145 (3.9) |
238U, g |
1800 |
235U, g |
110 |
239Pu,g |
3.2 |
239Pu,g (4 cm Pb) |
340 |
252Cf, neutron/s |
20000 |
industrial AC network (115-230V range) | 47/63 Hz frequency |
built-in accumulator battery | 12 V DC (back-up). Accumulator battery enables continuous working of the monitor during 8 hours (no less than 8 hours). |
no more then | 120 V•А. |